![Anest Iwata DVSL-100C Instruction Manual Download Page 17](http://html.mh-extra.com/html/anest-iwata/dvsl-100c/dvsl-100c_instruction-manual_2943112017.webp)
-15-
How to wire
①
Remove 4pcs. of M5 bolt at motor terminal box and remove protection cover.
※
Be careful not to lose removed M5 bolts and washer.
②
Wiring diagram is shown inside protection cover.
You can change to a 100V or 200V connection by changing terminal plate (2pcs.).
※
※
※
※
It is wired to 100V when delivered to you.
③
If you want to change to a 200V connection, remove M5 nut of electric source
terminal and change terminal plate as illustrated below.
④
Connect electric cable to terminal by using cable-gland at
φ
22mm hole of motor
terminal box.
⑤
Insert electric wire through cable gland on the bottom side of terminal box.
⑥
Connect each phase L-N to each electric source terminal respectively in
accordance with the below wiring diagram.