- 2 -
■
Parts list
No. Description
Qty
1
Nozzle
1
2
Lock Nut
1
3
Filter
1
4
Filter Cover
1
5
Ball Valve
■
How to operate
1. Connect air hose on Air Inlet.
2. Set inlet air pressure 0.1MPa (1.0bar/14psi) - 0.68 MPa (6.8bar/98psi).
3. Tighten Nozzle to full close position.
4. Loosen the Nozzle and adjust airflow. Loosening Nozzle approximately 40
degrees from full close position will achieve max airflow.
5. Adjust inlet air pressure if necessary.
6. Hand tighten Lock Nut to secure Nozzle.
Manual No. T496-01
Code No.
03455950
3176,Shinyoshida cho, Kohoku-Ku,
Yokohama 223-8501, Japan