Release Date 9 July 2021
Anemoment LLC
COMMAND
DESCRIPTION
offset [<value>] (x1 or x4)
Set or Show the offset value for all paths. This is
one of the calibration factors set during the
calibration cycle. If you enter the value as a
single number, it will be applied to all four
distances. If you enter four values, they will be
applied respectively to the four distance values.
The offset value compensates for variations in
manufacturing.
orientuv [std | ati | otsm]
Set or View the UV Wind Vector Output
coordinate system. There are some different
definitions for the meanings of the U and V axis.
The “std” setting defines positive U as being from
the West, and positive V as being from the
South. The “ati” setting defines the positive U as
being from the North, and positive V as being
from the West. The “otsm” setting matches the
original TriSonica Mini output definition of
positive U as being form the North, and positive
V as being from the East.
paramdelim [<delim> | space]
Get or Set the Parameter delimiter for all
Display Parameters
pressurecalibrate [slope <slope>|offset <offset>]
Gets or sets the slope and offset pressure
calibration factors. This command allows the
Users to add their own slope and offset values
to the pressure senor output. Note that the
pressure is transferred through the GorTex vent
on the bottom of the TSM and can take several
seconds to equalized with there is a rapid
change in pressure. Using the command
without parameters returns the current slope
and offset values. Providing the slope and offset
parameter values sets these values for the
pressure sensor.
protocol [232|422 [now]]
Show or set the current serial protocol setting.
The command only works for the TSM-PM,
where the EIA422 signals are brought out to the
connector. This is the software command to
select between EIA232 and EIA422 modes. The
“now” parameters makes the change
immediately, otherwise the change happens
after a system reset. – TSM-PM Only