COMMAND

 

DESCRIPTION

 

offset [<value>] (x1 or x4) 

Set or Show the offset value for all paths. This is 

one of the calibration factors set during the 

calibration cycle. If you enter the value as a 

single number, it will be applied to all four 

distances. If you enter four values, they will be 

applied respectively to the four distance values. 

The offset value compensates for variations in 

manufacturing. 

orientuv [std | ati | otsm]

 

Set or View the UV Wind Vector Output 

coordinate system. There are some different 

definitions for the meanings of the U and V axis. 

The “std” setting defines positive U as being from 

the West, and positive V as being from the 

South.  The “ati” setting defines the positive U as 

being from the North, and positive V as being 

from the West.  The “otsm” setting matches the 

original TriSonica Mini output definition of 

positive U as being form the North, and positive 

V as being from the East.

 

paramdelim [<delim> | space] 

Get or Set the Parameter delimiter for all 

Display Parameters 

pressurecalibrate [slope <slope>|offset <offset>]

 

Gets or sets the slope and offset pressure 

calibration factors. This command allows the 

Users to add their own slope and offset values 

to the pressure senor output. Note that the 

pressure is transferred through the GorTex vent 

on the bottom of the TSM and can take several 

seconds to equalized with there is a rapid 

change in pressure. Using the command 

without parameters returns the current slope 

and offset values. Providing the slope and offset 

parameter values sets these values for the 

pressure sensor.

 

protocol [232|422 [now]] 

Show or set the current serial protocol setting. 

The command only works for the TSM-PM, 

where the EIA422 signals are brought out to the 

connector. This is the software command to 

select between EIA232 and EIA422 modes.  The 

“now” parameters makes the change 

immediately, otherwise the change happens 

after a system reset. – TSM-PM Only

 

 

 

Summary of Contents for TriSonica Mini

Page 1: ...ANEMOMENT LLC TriSonica Mini Sensors User Manual...

Page 2: ...0 Release Date 9 July 2021 Anemoment LLC...

Page 3: ...Release Date 9 July 2021 Anemoment LLC ANEMOMENT LLC TriSonica Mini Sensors User Manual 2021 Anemoment LLC 353 Main Street Longmont CO 80501 Phone 720 600 7241 Fax 720 223 7504 Email info anemoment co...

Page 4: ...2 Release Date 9 July 2021 Anemoment LLC NOTES Sensor Unit Numbers ___________________________________________________ Purchase Date _________________________________________________________...

Page 5: ...Composition 9 Orientation 9 TSM FB 9 Considerations for User Supplied Mounting Platform for TSM FB 10 TSM FB Tripod Mounting Plate 10 TSM PM 10 TSM PM Tripod Adapter 10 Connecting Up 11 TSM FB 11 Con...

Page 6: ...Scale Command wd540 27 Non Volatile Parameters 27 TSM Sensor Meteorological Data Collection 29 Humidity 29 Absolute Pressure 29 Tilt 29 Compass 29 TROUBLESHOOTING your TriSonica Mini Sensor 31 Common...

Page 7: ...DRAWINGS use the Table of Contents in this User Manual to find information you seek The TriSonica Mini Family of Products 1 TSM WS TriSonica Mini Wind Sensor discontinued 2 TSM FB TriSonica Mini Wind...

Page 8: ...investment and we understand that each User has a unique idea they want to create You know best what you are trying to accomplish We know the TSM Sensors can help you access essential and actionable w...

Page 9: ...for such additional data or processing Sorry No Apples Today The data stream from the TSM Sensor can be received stored and interpreted by the User s choice of device so long as it is connected to th...

Page 10: ...8 Release Date 9 July 2021 Anemoment LLC...

Page 11: ...d gray patina ideal for minimizing visual presence of the system The connecting posts are carbon fiber tubes Orientation The TSM Sensors have a north arrow indicator N marked on one of the upper arms...

Page 12: ...edule 10 pipe or 22 mm Carbon Fiber Tube The pipe must be a thin wall type as indicated by the Schedule 10 designation to allow an inside diameter wide enough to let the mating cable connector pass th...

Page 13: ...formation Connecting the TSM FB to Other Anemoment Products USB ADAPTER Open the Adapter case and insert the wires exiting the TSM FB into the terminal block by color as labeled on the circuit board T...

Page 14: ...re TSM PM The TSM PM contains a female 12 Pin circular connector that connects to a male 12 Pin Circular IP67 connector Cables with connectors may be purchased from Anemoment in 2m 5m 10m and 20m leng...

Page 15: ...2 Mode and TX data output in EIA422 mode 5 GREEN TX Serial Transmit data output TX in EIA422 mode Not used in EIA232 mode 6 BLUE RX Serial Receive data input in EIA232 Mode and TX data output in EIA42...

Page 16: ...t match the labels printed on the USB Adapter circuit board A helpful video demonstrating this connection is available at Anemoment com resources DATA LOGGER Circuit Board Only Use a Single Terminated...

Page 17: ...utputs data in an ASCII character string ending with carriage return and line feed characters Each line is a single record of all the measured parameters contained in a single sample The parameters on...

Page 18: ...ds S 05 2 D 112 U 01 9 V 04 7 W 01 1 T 22 6 S 05 3 D 107 U 01 5 V 04 9 W 01 3 T 22 2 Error Codes When the TriSonica Mini firmware detects an error it outputs an error code in the data stream in all th...

Page 19: ...ng by listening for a quiet rapid clicking sound made by the transducers This sound is a mechanical artifact from a transducer initiating an ultrasonic sound not the ultrasonic sound itself Serial Com...

Page 20: ...Diagnostic Runs built in diagnostics and displays the results G Instrument Reset Resets the instrument clearing all volatile memory restoring to non volatile memory settings X Exit without storing cha...

Page 21: ...the number of decimals places of a Display Parameter or a Group of Parameters See the Show Hide Tag Untag and Decimal Commands section in this document declination value Set Read the true heading dec...

Page 22: ...nds section in this document systemreset Software Reset tag param Display the ID Tag of a Display Parameter or a Group of Parameters See the Show Hide Tag Untag and Decimal Commands section in this do...

Page 23: ...tween transducers This is one of the calibration factors set during the calibration cycle If you enter the value as a single number it will be applied to all four distances If you enter four values th...

Page 24: ...positive U as being form the North and positive V as being from the East paramdelim delim space Get or Set the Parameter delimiter for all Display Parameters pressurecalibrate slope slope offset offs...

Page 25: ...character One command per set of curly braces The open curly brace instructs the TSM that a API command is starting and the close curly brace indicates the end of the command When the close curly bra...

Page 26: ...tag for a measurement or adjust the number of decimals for an output respectively When invoked without a parameter they display the options available The show command only lists the values that are av...

Page 27: ...humidity If humidity is not supplied then 50 is assumed The calibration cycle takes ten seconds You will see dots printed on the serial console indicating progress and the serial prompt will return wh...

Page 28: ...he chamber conditions to settle the calibration routine of our software runs the math and physics equations backwards in a sense to calculate the exact distance between pairs of transducers down to th...

Page 29: ...ingle large transition once at 540 degrees and again at 180 degrees to display data Non Volatile Parameters The TriSonica Mini operates with a copy of its configuration parameters in volatile memory R...

Page 30: ...28 Release Date 9 July 2021 Anemoment LLC...

Page 31: ...and it displayed humidity greater than 100 until the condensation evaporated and equalized through the vent Absolute Pressure The absolute pressure sensor is located inside the TriSonica Mini and depe...

Page 32: ...30 Release Date 9 July 2021 Anemoment LLC...

Page 33: ...u ve checked this twice and you still hear no sound please contact us at info anemoment com for further steps Symptom There is no serial data coming from the TSM Sensor Action Refer to the CONNECTION...

Page 34: ...dem Send Select the file to upload and press Enter Updating TSM Sensor Bootloader New in 2 0 In the TriSonica Mini program memory are two programs the TriSonica Sensor application and a bootloader Dur...

Page 35: ...LIED WARRANTIES OF MERCHANTABILITY FITNESS FOR A PARTICULAR PURPOSE AND NON INFRINGEMENT NO ADDITIONAL REPRESENTATION OF WARRANTY INCLUDING BUT NOT LIMITED TO STATEMENTS OF CAPACITY SUITABILITY FOR US...

Page 36: ...gure 9 Listen for TSM Sensor Operation 31 List of Tables________________________________ Table 1 TSM SENSOR COMPARISON GUIDE 6 Table 2 TSM FB to DATA LOGGER SCREW TERMINAL WIRING POSITIONS 11 Table 3...

Reviews: