12
10 - Accuracy Indicator:
Indicates five levels of accuracy selec-
tions: ULTRA FINE, SUPER FINE, FINE, MEDIUM and COARSE.
Refer to page 20 (Specifications) for the specific values for each
accuracy selected. No center bar is displayed for calibration mode.
Refer to page 14. This mode is intended only for calibration of
rotational lasers and not for normal operation.
METOR allows two different mounting positions for the rod clamp
which are detected automatically.
NOTE:
Other clamps than the original METOR clamp can not be
detected by METOR and can lead to measuring errors in offset
position.
11 - Offset on-grade clamp position:
Clamp position is sensed
automatically and displayed. Offset clamp position moves the
on-grade location to allow more grade information to be
displayed above grade. This is useful in applications where going
below grade is not required, i.e. driving stakes down to grade.
This symbol is blinking if a user defined on-grade position is set.
Refer to page 13.
12 - Center on-grade position:
Clamp position is sensed
automatically and displayed. Standard center position displays
an equal amount of information above and below grade.
See chapter 11 for further information about the rod clamp.
13
9 Advanced Functions / Memory
Capture / Timer:
The Capture function is used to obtain a
single reading and keep it displayed. This may be useful
when the unit may not be visible and grade information needs
to be obtained.
When in the laser beam and power on, momentarily press the
Power/Capture switch. The current elevation reading will be saved.
A flashing display will confirm the reading has been captured. Press
any switch to return to normal operation.
When out of the laser beam and power is on, momentarily press the
Power/Capture switch. A short intermittent beep and 'WAIT'
displayed on the LCD confirm the Timer mode. (The beeper will turn
on to Low if it was turned off.) Place the receiver in the beam. The
beeper will chirp rapidly after approximately five seconds confirming
beam capture. A flashing display will also confirm the reading has
been captured. Press any switch to return to normal operation.
Memory:
Memory key allows storing and displaying stored
measurements.
After pressing the Memory key while displaying a
measurement (while in beam or with a captured measurement), the
Slot number will blink below the measurement value. The slot
number can be scrolled with the arrow keys (Accuracy and Volume
keys). The measurement is stored to the selected slot by pressing
the Memory key a second time.
CAUTION:
potentially existing
measurement in this slot will be overwritten. Power key cancels
storing procedure.
Pressing the Memory key while no measurement is displayed,
shows the contents of memory (stored measurement and slot
number). Pressing Memory key for two seconds deletes the current
slot ("DEL" is displayed).
Pressing the Memory key for two seconds outside memory display
jumps to Memory menu (refer to page 17).