![background image](http://html1.mh-extra.com/html/androtec/metor/metor_operators-manual_2942876010.webp)
16
LO
(Low) uses minimum averaging to display laser strikes.
MD
(Medium) is default setting and used for most applications.
HI
(High) can be used in windy conditions, when the laser beam
may be unstable, or when working at long distances.
NOTE:
Refer to the laser's specifications for accuracy and distance infor-
mation.
D.R.O. - Digital Read Out (OF / DB / HI):
Turns the numeric display
ON (DB) or OFF (OF) or selects high resolution display mode (HI).
Default setting is ON (DB).
UNIT - Units of Measure:
Centimeters (CM), millimeters (MM),
inches (IN) or feet (FT). Default is MM.
ARRW - Arrow Display (DB / PR):
Adjusts how the off-grade arrow
and bars are displayed. Default is DB.
DB
(Deadband): each bar represents the deadband or accuracy
setting.
NOTE:
For larger deadbands, not all bars may be
displayed.
PR
(Proportional): Each bar represents the available vertical
reception range divided by the number of segments.
O.O.B - Out-of-Beam Display (ON / OF):
When ON a sequence of
arrows is displayed that indicates when the receiver has moved
beyond the vertical laser reception range. The sequence will indicate
which direction to move to get back in the laser beam. The display
remains on for approximately 25 seconds. Default setting is OF.
GRD.A. - Grade Alarm (ON / OF):
Special application function that
when turned ON, disables the audible signal when on-grade. When
moved out of the on-grade deadband, the beeper activates as
normal. Default is OFF (OF).
17
A.S.O. - Automatic Shut Off (OF / 0.5 / 24):
Selects automatic
shutoff time from last laser strike.
OF:
Automatic shutoff turned Off.
0.5:
30 minute shutoff. Default setting.
24:
24 hour shutoff.
TX.O.L. - Transmitter Out-of-Level (OF / 2.3 / 2.7 / 3.3 / 5.0 / 6.7):
Special Application used with transmitters which communicate to the
receiver that the laser is out of level. The lasers change their rotating
speed when they are out of level. When enabled, the receiver
senses this change and alerts the user. Grade display information is
disabled when activated.
NOTE:
Refer to page 20 for RPM
equivalents. Default is OFF (OF).
TX.L.B. - Transmitter Low Battery (OF / 2.3 / 2.7 / 3.3 / 5.0 / 6.7):
Special Application used with transmitters which communicate to the
receiver that the laser has a low battery by changing their rotating
speed. When enabled, the receiver senses this change and alerts
the user to a laser low battery condition.
NOTE:
Refer to page 20 for
RPM equivalents. Default is OFF (OF).
INFO - Information (RPS / VER / MODL / S/N):
The symbol "
"
indicates a sub menu. Press the Memory key to enter (
).
RPS:
Displays laser Revolutions Per Second for current laser
strikes.
NOTE:
Refer to page 20 for RPM equivalents.
VER:
Displays software version
MODL:
Displays model information
S/N:
Displays serial number