Maintenance
57
MAXXfl o EVO
6.2.4 LMS14 PCB REPLACEMENT
ATTENTION: Electrostatic sensitive PCB - Handle PCB by edges only and if
available wear an earth wristband
This is located on the bridge. It is important that the correct PCB replacement is used. Check that the model
matches the replacement PCB
• Carefully push off all the connectors on the PCB (be careful not to pull on the wires).
• Release in turn, all seven PCB support posts by squeezing the barb together at the end of the support
and withdrawing the board from each support, one at a time.
• Replacement is the reverse.
6.2.5 SPARK GENERATOR
• Remove the power connections
• Remove the ignition cable
• Remove the 2 fi xing screws
•
Replacement is the reverse
Support post
Power connections:
White = 1
Red = 2
Fixing screws
W
W
R
R