“DIRECT SPARK” IGNITION (DSI) SYSTEM COMPONENTS
(ALL MODELS EXCEPT EC380/1900)
Honeywell S9380B1001C Direct Spark Ignition Control, CE
listed. 3 Trials for Ignition, 30 second pre-purge timing, 4 second
trial for ignition, 24 volt input to control and integrated
temperature/high limit control.
PSE spark and flame sense rods.
Honeywell VK8115 gas valve (negative pressure regulator) with
matched venturi sizes for mixing gas with combustion air.
EBM RG130 (36-6 and 43-9 kW/hr. input sizes) and RG148 (58-
3 through 85-0 kW/hr. inputs) pre-mix combustion blowers. 230
volts, 50/60 Hz.
Burner: Acotech (Bekaert Combustion Technology) Pre- mix
burner with stainless steel mesh outside knit.
Blocked Vent Pressure Switch: Honeywell IS20378-5770
normally closed pressure switch. Contacts open in the event of a
severe blockage of the flue outlet.
5.10 Direct spark
THERMOSTAT AND HIGH LIMIT CONTROLS
(EC380/1900 MODEL ONLY)
Honeywell L6189A 2043B aquastat. Temperature adjustment
range: Below 40°C to maximum of 82°C (dial stop to limit
maximum temperature). Differential set to 4°C Capillary bulb
inserts into well in top of tank. Thermostat dial adjustable on top
front section of water heater jacket.
Honeywell L6189C 2023 1 High limit control. Set point fixed to
93°C with screw. Mounted to control panel inside control
compartment. Capillary bulb inserts into separate well in top of
tank. Manual reset control button accessible through clearance
hole in control panel.
THERMOSTAT AND HIGH LIMIT CONTROLS
(ALL MODELS EXCEPT EC380/1900)
Honeywell S9380B1001C Direct Spark Ignition Control.
Temperature adjustment range: 21°C to maximum of 85°C.
Differential set to 5°C. Honeywell sensor bulb 5000-1464 series
is inserted into drywell.
5.11 Thermostat and high limit