background image

 

Meter Screen Display Message 

 

The method of fixing battery   

1、Slide and remove the battery cover according to the graphical representation direction 

2、Insert two AAA size batteries, and confirms well positive and negative extremely. 

3、Slide battery cover back into place. 

   

  Note: Discard the used battery according to the local law. 

 

Test Strip 

The  Test  Strips  are  designed  to  work  only  in  conjunction  with  the  Glucose  Meter. 
Each  strip  can  be  used  only  once.  The  Glucose  AG-605A  Test  Strip  consists  of  the 
following parts: 

 

Test Strip Vial label 

Summary of Contents for AG-605A

Page 1: ...m if it is not working properly or if it has suffered any damage Do not let the Blood Glucose Monitoring System come into contact with surfaces which are too hot to touch Do not block test ports nor p...

Page 2: ...mm L 50mm W 22mm H 3 Weight 60g exclude batteries 4 Measuring method Amperometric technology using glucose oxidase 5 Measuring range 20 mg dL 600 mg dL 1 1 mmol L 33 3mmol L 6 Measurement unit mg dL o...

Page 3: ...test strip Avoid making the liquid into the test strip and the button Avoid getting water or any other solution inside the meter Blood Sample The fresh capillary vessel whole blood finger tip blood or...

Page 4: ...ize batteries and confirms well positive and negative extremely 3 Slide battery cover back into place Note Discard the used battery according to the local law Test Strip The Test Strips are designed t...

Page 5: ...the date setting Short press and release the MEM button until the correct date appears 5 With the correct date on the display short press and release the S button to bring up the time setting The hou...

Page 6: ...ired Testing Your Blood Glucose Level Before testing you will need the following items Glucose AG 605A Meter AGS 1000 test strip Adjustable Automatic Lancing Device Sterile Lancet CAUTION To reduce th...

Page 7: ...Replace the end cap back on the body of the lancing device 5 Pull back on the cocking mechanism until it comes to a stop 6 Place the lancing device firmly against the sample site and press the release...

Page 8: ...f the same result occurs consult your healthcare professional immediately Step 10 If a LO message appears on your display your Glucose Meter has detected that your blood glucose level is lower than 20...

Page 9: ...t strip Control solution If long press the S button for about two seconds in step5 the CTL will appear on the screen which means that the test is under the CTL condition and the result will not be sto...

Page 10: ...aning the andon Blood Glucose Monitoring System gently wipe the exterior surface using a damp soft cloth AVOID USING ANY ORGANIC SOLVENT for cleaning Discard the used lancet properly in accordance wit...

Page 11: ...countdown The meter is calculating the result At the end of the count down the meter will display the test result No action required Blood glucose level is lower than 20mg dl 1 1mmol L The message in...

Page 12: ...12 Display the result Do nothing Demonstrates the memory the serial number Do nothing Memory result demonstration Do nothing No memory in meter Do nothing Result display is end Do nothing...

Page 13: ...libration Please contact us Use a used test strip Please use a new strip and re test Meter internal memory unit error Reinsert the CODE bottle please contact us if it appear for three time Environment...

Page 14: ...e number printed on the Test Strip vial Incorrect Code numbers has been inputted into the Meter Insert the new CODE card to match the Code number on the Test Strip vial label Test results are inconsis...

Page 15: ...15 15minutes before performing a new test The Meter countdown did not start Test Strip has not been inserted correctly Use a new Test Strip and redo the test...

Page 16: ...erature limitation Expired Date Anti garbage Lotus Global Co Ltd 47 Spenlow House Bermondsey London SE16 4SJ Andon Health Co Ltd Register Address No 3 JinPing Street Ya An Road Nankai District Tianjin...

Reviews: