1-3 Specifications 

Battery mass 

 Approximately 1.3 kg 

Operating temperature range 

 +5

°

C to +40

°

C (+41

°

F to +104

°

F) 

Storage temperature range 

 -20

°

C to +40

°

C (-4

°

F to +104

°

F) 

Operation hours 

 Approximately 8 hours (when operated continuously using a GX 

series balance. Operation hours depend on operating conditions.) 

Charging time 

 Approximately 15 hours 

Charging method 

 Charge with timer function for an automatic stop 

External dimensions 

 58 (H) x 96 (W) x 140 (D) mm 

Output voltage 

 12 V (500 mA max.) 

Battery type 

 Nickel-metal-hydride (Ni-MH) battery 

 

Output cable length 

 Approximately 1 m 

 

 

1-4  List of Applicable Balances 

Use the AD-1682 only with balances listed below. 

Balances 

Continuous operation hours 

(Depends on operating conditions) 

HX series 

 

5 hours 

GP series, GX-K/GF-K series 

 

6 hours 

FC series, FP series, GH series, GR series, GX/GF series, 

HM series, HP series, HR-202, HR-300, HR-

i

 series 

 8 

hours 

ET-W series, HF series, HR-60, HR-120, HR-200 

16 hours 

EK-G series, EK-H series, EW-G series 

28 hours 

HC series, HD series 

66 hours 

 
The AD-1682 can be used for other instruments than balances as shown below. 

Instruments 

Continuous operation hours 

(Depends on operating conditions) 

SV series (Viscometer) 

 

5 hours 

AD-8922 (Remote controller) 

12 hours 

Note 

In this manual, "balance(s)" refers to the A&D-manufactured products listed in the tables above. 

 

 

1-5  Notes on Using the AD-1682 

 

The continuous operation hours depend on the operating conditions. 

 

The battery, while it is being charged, will not supply power to the balance. 

 

Do not short-circuit the output plug. 

 

The battery may self-discharge while it is left unused for a long period of time. Charge the 

battery after a long period of non-use. 

 

The balance, after the display is turned off using the ON/OFF key, is still consuming power. To 

turn the power off completely, disconnect the charger from the battery and turn the power 

switch to the “CHARGE” position. (If the charger is connected to the battery under this 

condition, the battery will start charging.) 

 

Every time the power switch is turned to the “CHARGE” position with the charger connected to 

the battery, the battery will start charging. Charging the battery before it is completely 

discharged will shorten the battery life. 

Summary of Contents for Rechargeable Battery AD-1682

Page 1: ...WM PD4000270C ...

Page 2: ...duced transmitted transcribed or translated into any language in any form by any means without the written permission of A D Company Ltd The contents of this manual and the specifications of the instrument covered by this manual are subject to change for improvement without notice ...

Page 3: ...o be used with balances manufactured by A D Using the AD 1682 with products other than specified may cause heat buildup and could cause a fire Before use see 1 4 List of Applicable Balances to check which balances can be powered by the AD 1682 Keep the battery out of the reach of children Do not drop or apply shock to the battery Compliance Compliance with FCC Rules Please note that this equipment...

Page 4: ... see 1 4 List of Applicable Balances to check which balances can be powered by the AD 1682 1 2 Unpacking the AD 1682 In the carton you should find this manual and the following Battery unit 1 pc 800 mA time delay fuse 1 pc Battery charger 1 pc Please confirm that this charger type is correct for your local voltage and receptacle type Identification label 1 pc Paste this label onto the battery char...

Page 5: ... 66 hours The AD 1682 can be used for other instruments than balances as shown below Instruments Continuous operation hours Depends on operating conditions SV series Viscometer 5 hours AD 8922 Remote controller 12 hours Note In this manual balance s refers to the A D manufactured products listed in the tables above 1 5 Notes on Using the AD 1682 The continuous operation hours depend on the operati...

Page 6: ...harger is not enough Use the specified charger and confirm the voltage of the power source Charge the battery as follows 1 Make sure that the battery is completely discharged When the battery is completely discharged With the charger disconnected when the power switch is turned to the POWER SUPPLY position the POWER SUPPLY LED indicator will be off If the balance can detect the low battery lb is d...

Page 7: ...ower to the balance 5 While the balance is in use if the remaining charge decreases and the voltage drops the POWER SUPPLY LED indicator will be turned off automatically to shut off the battery Under this condition turn the power switch to the CHARGE position to protect the battery Note Much care is required with the connection as illustrated at the right The charger and the battery are connected ...

Page 8: ...the balance CHARGE Connected The output voltage of the battery charger is not enough Use the specified charger and confirm the voltage of the power source CHARGE Not connected None POWER SUPPLY Not connected The battery is supplying power to the balance See note 2 POWER SUPPLY Connected The charger is supplying power to the balance Note 1 Charge the battery after it is completely discharged Note 2...

Page 9: ...7 MEMO ...

Page 10: ...8 MEMO ...

Reviews: