background image

 

1

Warning Definitions 

The warnings described in this manual have the following meanings: 

 

Caution 

A potentially hazardous situation which, if not avoided, may result in minor or moderate injury. 
It may also be used to alert against unsafe practice. 

 

Note 

An important description for proper use of the instrument. 

 

 

Precautions 

 Caution

 

 

Do not heat the battery, disassemble or dispose of in fire. It may build up heat, explode, or leak and 
cause a fire. Follow the local regulations when disposing of a used battery. 

 

Do not allow the battery to become wet. It may build up heat or cause a fire. 

 

Recharge the battery only after the battery has been discharged completely. Charging the battery 
repeatedly, with incomplete discharging, may result in heat buildup, generating gases or leaking. 

 

When charging the battery, use the charger provided with the battery. Using a charger other than 
the one provided may cause heat buildup and could cause a fire. 

 

The AD-1682 is designed to be used with balances manufactured by A&D. Using the AD-1682 with 
products other than specified may cause heat buildup and could cause a fire. Before use, see “1-4 
List of Applicable Balances” to check which balances can be powered by the AD-1682. 

 

Keep the battery out of the reach of children. 

 

Do not drop or apply shock to the battery. 

 

 

Compliance 

Compliance with FCC Rules 

Please note that this equipment generates, uses and can radiate radio frequency energy. This 
equipment has been tested and has been found to comply with the limits of Class A computing device 
pursuant to Subpart J of Part 15 of FCC rules. These rules are designed to provide reasonable 
protection against interference when the equipment is operated in a commercial environment. If this unit 
is operated in a residential area it may cause some interference and under these circumstances the 
user would be required to take, at his own expense, whatever measures are necessary to eliminate the 
interference. 

(FCC = Federal Communications Commission in the U.S.A.) 

 

Compliance with EMC Directives   

This device features radio interference suppression in compliance with valid EC 
Regulation 89/336/EEC. 

Summary of Contents for Rechargeable Battery AD-1682

Page 1: ...WM PD4000270C ...

Page 2: ...duced transmitted transcribed or translated into any language in any form by any means without the written permission of A D Company Ltd The contents of this manual and the specifications of the instrument covered by this manual are subject to change for improvement without notice ...

Page 3: ...o be used with balances manufactured by A D Using the AD 1682 with products other than specified may cause heat buildup and could cause a fire Before use see 1 4 List of Applicable Balances to check which balances can be powered by the AD 1682 Keep the battery out of the reach of children Do not drop or apply shock to the battery Compliance Compliance with FCC Rules Please note that this equipment...

Page 4: ... see 1 4 List of Applicable Balances to check which balances can be powered by the AD 1682 1 2 Unpacking the AD 1682 In the carton you should find this manual and the following Battery unit 1 pc 800 mA time delay fuse 1 pc Battery charger 1 pc Please confirm that this charger type is correct for your local voltage and receptacle type Identification label 1 pc Paste this label onto the battery char...

Page 5: ... 66 hours The AD 1682 can be used for other instruments than balances as shown below Instruments Continuous operation hours Depends on operating conditions SV series Viscometer 5 hours AD 8922 Remote controller 12 hours Note In this manual balance s refers to the A D manufactured products listed in the tables above 1 5 Notes on Using the AD 1682 The continuous operation hours depend on the operati...

Page 6: ...harger is not enough Use the specified charger and confirm the voltage of the power source Charge the battery as follows 1 Make sure that the battery is completely discharged When the battery is completely discharged With the charger disconnected when the power switch is turned to the POWER SUPPLY position the POWER SUPPLY LED indicator will be off If the balance can detect the low battery lb is d...

Page 7: ...ower to the balance 5 While the balance is in use if the remaining charge decreases and the voltage drops the POWER SUPPLY LED indicator will be turned off automatically to shut off the battery Under this condition turn the power switch to the CHARGE position to protect the battery Note Much care is required with the connection as illustrated at the right The charger and the battery are connected ...

Page 8: ...the balance CHARGE Connected The output voltage of the battery charger is not enough Use the specified charger and confirm the voltage of the power source CHARGE Not connected None POWER SUPPLY Not connected The battery is supplying power to the balance See note 2 POWER SUPPLY Connected The charger is supplying power to the balance Note 1 Charge the battery after it is completely discharged Note 2...

Page 9: ...7 MEMO ...

Page 10: ...8 MEMO ...

Reviews: