Page
74
9.
9.
9.
9.
Int
Int
Int
Interface
erface
erface
erface
9.1.
9.1.
9.1.
9.1.
Control I/O Function
Control I/O Function
Control I/O Function
Control I/O Function
The control I/O is the interface to communicate system status and sequence
commands between the indicator and peripherals.
Input terminals ...................11 lines that can be selected by the function
Output terminals ................11 lines that can be selected by the function
The output terminals use open collector transistors
Preset the functions to these terminals. Refer to "11. Function List".
[Function] - [Set function] - [Control I/O]
Caution
Do not assign the same function to multiple terminals of the control I/O and OP-05.
9.1.1.
9.1.1.
9.1.1.
9.1.1.
Interface Circuit
Interface Circuit
Interface Circuit
Interface Circuit
Input terminal
Maximum
typ.
Input open voltage
14V DC
10 V DC
Input drive current
5 mA
3 mA
Saturation tolerance voltage
2 V DC
Output terminal
Maximum
Output voltage
40 V DC
Output current
50 mA
Saturation tolerance voltage
1.5 V at 50 mA
Max. 5 mA
DC 8 ~ 14V
A12
Input common terminal
A1 ~ A 11
Input terminal
or
or
It is recommend that you use :
Mechanical switch or
open collector transistor.
Vsat < 2 V
Max. 40V DC
It is recommend that you use :
Mechanical relay with surge diode or
photo coupler.
B12
Output common terminal
B1 ~ B 11
Output terminal
Interface circuit in
the indicator
Max. 50 mA
Vsat < 1.5 V at 50 mA
Use a surge clamping diode to protect
the solenoid or relay from noise.