Page
57
8.9.
8.9.
8.9.
8.9.
BUSY Output
BUSY Output
BUSY Output
BUSY Output
The BUSY output is turned on at loading the article on the weighing conveyor.
The BUSY output is turned off until it classifies with the selector.
And the AD-4404 can control up to ten articles continuously.
If an article is loaded on the weighing conveyor after the busy state is off, it can avoid
duplication and crush of the articles. It is effective to have a long weighing interval.
The BUSY signal is output on the following condition.
The BUSY signal is output, when the following timer is counting.
Eval delay timer
[
5q f-43
]
Average timer
[
5q f-44
]
Selection out 1 delay timer
[
5q f-46
]
Selection out 2 delay timer
[
5q f-47
]
Selection out 3 delay timer
[
5q f-48
]
Selection out 4 delay timer
[
5q f-49
]
Selection out 5 delay timer
[
5q f-50
]
Selection out 6 delay timer
[
5q f-51
]
Select output 1 timer
[
5q f-52
]
Select output 2 timer
[
5q f-53
]
Select output 3 timer
[
5q f-54
]
Select output 4 timer
[
5q f-55
]
Select output 5 timer
[
5q f-56
]
Select output 6 timer
[
5q f-57
]
8.10.
8.10.
8.10.
8.10.
Stop Input during BUSY
Stop Input during BUSY
Stop Input during BUSY
Stop Input during BUSY
Procedure for a stop input during operation:
1 When a stop input is entered while BUSY is turned on, the status changes to
pause.
2 All timers are held. Status indicators blink.
Procedure to continue the current weighing:
1 When an operation input is entered during pause, all timers restart counting.
Procedure for a stop input during pause:
1 When a stop input is entered during pause, status changes to stop mode.
2 All timers are reset. Status indicators are turned off.
Refer to " 4.2.2. Status of Weighing Mode".