Page
63
8.17.
8.17.
8.17.
8.17.
Tare Operation
Tare Operation
Tare Operation
Tare Operation
The relation of the display is as follows:
Net = Gross - Tare
Key Operation
Press
the
TARE
key.
Operation from Control I/O
[
1n f-
xx
]
[
03
]
In
xx
(A
xx
)
.................The input terminal of the control I/O.
Tare
................................When it turns on, zero of net is displayed.
xx is terminal number (01 to 11).
[Function] - [Set function] - [control I/O] - [Input]
Concerning Parameters
[
genf-9
]
Tare & zero unstable WGT
The prohibition of the re-zero operation in the unstable condition.
[Function] - [Set function] - [General] - [Weight]
[
genf-10
]
Tare at (-)gross weight
The prohibition of the tare operation during negative weighing.
[Function] - [Set function] - [General] - [Weight]
[
genf-13
]
Clear mode at power ON
Specify power-on status.
[Function] - [Set function] - [General] - [Weight]
8.17.1.
8.17.1.
8.17.1.
8.17.1.
Tare Clear Operation
Tare Clear Operation
Tare Clear Operation
Tare Clear Operation
The function displays a gross value that is not compensated by the tare operation or
the zero operation.
Key Operation
Step 1 Turn off the display.
Step 2 Pressing and holding the
TARE
key, press the
ON
key.
Operation from Control I/O
[
1n f-
xx
]
[
04
]
In
xx
(A
xx
)
.................The input terminal of the control I/O.
Tare clear
.................When it turns on, the original gross is displayed.
xx is terminal number (01 to 11).
[Function] - [Set function] - [control I/O] - [Input]
Summary of Contents for Check Weighing Indicator AD-4404