VENTING REQUIREMENTS :

HEIGHT & CLEARANCE:

 

   •  Vent system must terminate to the outside 

      (Roof or side wall). 

   •  DO NOT terminate the vent system in an attic or        

      other enclosed area. 

   •  DO NOT use 4" (10.2 cm) laundry-type wall caps. 

   •  Use metal/aluminum vent only. Rigid metal/ 

      aluminum vent is recommended. 

   •  DO NOT use plastic vent. 

   •  Always keep the duct clean to ensure proper     

      airflow. 

   •  Calculate the following figures before installation: 

Distance from the floor to the ceiling 

Distance between the floor to the    

          countertop/stove 

Distance between the cooking surface to the    

          range hood (recommend 24" to 30") minimum of    

          30" is required for gas stove top 

For the most efficient & quiet operation: 

   •  A distance of 24" to 30" is recommended between     

      stove top and the bottom of range hood. 30" 

      minimum is required for gaz stove tops. 

   •  It is recommended that the range hood be vented     

      vertically through the roof through 6" (15.3 cm) or     

      bigger round metal/aluminum vent work. 

   •  The size of the vent should be uniform. 

   •  Use no more than three 90° elbows. 

   •  Make sure there is a minimum of 24" (61 cm) of  

      straight vent between the elbows if more than one 

      elbow is used. 

   •  DO NOT install two elbows together. 

   •  The length of vent system and number of elbows     

      should be kept to a minimum to provide efficient 

      performance. 

   •  The vent system must have a damper. If roof or   

      wall cap has a damper, DO NOT use damper (if 

      supplied) on top of the range hood. 

   •  Use silver tape or duct tape to seal all joints in the 

      vent system. 

   •  Use caulking to seal exterior wall or roof opening 

      around the cap. 

      1. 

      2. 

      3. 

      4. Height of hood and duct cover. 

 

 

Min : 24” 

 

 

 

 

Min : 24” 

Max : 30” 

Maximum ceiling clearance

100" at 30" hood mounting

height above countertop or

stove. (may vary with

different model). Chimney

extensions available for

higher ceiling 

36” base

Min:24”

Max:30”

Support

Structure

Standard

Upper

Chimney

Standard

Lower

Chimney

Range hood

Countertop/Stove

* Higher ceiling requires chimney extension.

Available at your local resellers

Model # 

 

Aero Island 36

5

Height of hood and duct cover.

Summary of Contents for Aero Island

Page 1: ...tion regarding installation safety and maintenance Keep these instructions for future reference RANGE HOODS USER INSTRUCTIONS IMPORTANT SAFETY INSTRUCTIONS Carefully read the following important infor...

Page 2: ...may be affected by this unit s operation Follow the heating equipment manufacturer s guideline and safety standards such as those published by the National Fire Protection Association NFPA and the Ame...

Page 3: ...THE FIRE DEPARTMENT DO NOT USE WATER including wet dishcloths or towels a violent steam explosion will result Use an extinguisher ONLY if You know you have a Class A B C extinguisher and you already k...

Page 4: ...3...

Page 5: ...bigger round metal aluminum vent work The size of the vent should be uniform Use no more than three 90 elbows Make sure there is a minimum of 24 61 cm of straight vent between the elbows if more than...

Page 6: ...3 1 4 CALCULATING VENT SYSTEM LENGTH...

Page 7: ...xhaust air or terminate duct work into spaces between walls crawl spaces ceiling attics or garages All exhaust must be ducted to the outside Use metal aluminum duct work only Fasten all connections wi...

Page 8: ...a qualified electrician if you are not sure that the range hood is properly grounded DO NOT have a fuse in the neutral or ground circuit IMPORTANT Save this Installation Guide for electrical inspector...

Page 9: ...ris from entering the vent opening Determine and mark the center line on the ceiling where the range hood will be installed Make sure there is proper clearance within the ceiling or wall for exhaust v...

Page 10: ...ling must be at least 30 mm 1 18 in Drill 1 170 mm 6 7 round hole in the ceiling Run house electrical wires to the electrical box on the bracket Black to Black White to White and Green to Green or Bar...

Page 11: ...Electrical Wires...

Page 12: ...ng positions Repeat to install all baf e lters Step 5 Finishing installation Slide the inner flue up to the ceiling and attached it ceiling bracket using screws See fig 6 Remove the protective coating...

Page 13: ...5 6 2 7 1 2 3 4 5 6 7 8 9 10 11 Upper Lower Chimneys Motor Box Lights Light Covers Control Buttons Filters Hood Assembly Vent Damper Angle Mounting Brackets Ceiling Bracket Electrical Box 2 1 4 4 1 3...

Page 14: ...eed o Press the key again and the motor will reach Medium speed o Press the key once more and the motor will reach High speed o Press the Key to lower speeds in succession until the motor stops workin...

Page 15: ...ely secured Check if duct is clogged or if damper unit half circular flapper is not installed correctly or opening properly A tight mesh on a side wall cap unit might also cause restriction to the air...

Page 16: ...below...

Page 17: ...glove or use a cloth to handle the replacement bulb DO NOT handle with bare fingers as this may shorten the life of the bulb Push gently but securely into light socket NOTE DO NOT push too hard as bul...

Page 18: ...CIRCUIT DIAGRAM Total Input Power 410W...

Page 19: ...9 3 5 244mm 8 2 5 213mm 6 2 5 163mm 10 2 5 265mm 4 3 10 109mm 11 279mm 10 1 5 260mm 7 1 5 183mm 19 Model Aero Island 36 MOUNTING BRACKET...

Page 20: ...20 Model Aero Island 36 MEASUREMENTS AND DIAGRAMS 11 28 cm 11 29 35 89 8 cm 60 6 cm 23 1 3 7 cm 23 46 59 4 cm 117 9 cm...

Page 21: ...ELECTRICAL ASSEMBLY 21 Model Aero Island 36 BLOWER ASSEMBLY...

Page 22: ...is performed on the Product by any person not authorized by AMS to do so ii any alleged material defect including deterioration or wear is a result of failure to observe the manufacturer s instructio...

Reviews: