The element needs to be wired to single phase 220v. It should be positioned in the
tank angled to the center making sure it does not interfere with the agitator shaft
or CIP spray balls.
The Rheostat control allows you to
adjust the amount of electrical
current running to the heating
element and control the heat of the
air space. The Rheostat needs to be
installed by a licensed electrician.
The Air Space Heater fits into a 3”
sanitary ferrule and element is self
supporting. The top agitation blade
helps move the air in the head space.
Anco Electric Air Space Heater
18
Summary of Contents for Batch Pasteurizer
Page 16: ...9 25 2018 16 Figure 1 Figure 2...
Page 19: ...Ground To be installed by a licensed electrician 19 Anco Electric Air Space Heater...
Page 20: ...Anco Airspace Heater Element 20...
Page 23: ...9 25 2018 23 Spray Ball Installation and Maintenance...