Send Program to Controller Send current program to the controller.
View Program in Controller
View program in the controller memory.
Upload Program in Controller Upload the program in the controller for editing and saving.
Enable Autostart
Program will start when controller is powered up.
Disable Autostart
Program will only execute when run is clicked.
Run
Execute the program in the controller memory.
Stop
Abort program execution.
Add
Adds a new line of code to the end of the program.
Change
Edits the currently selected line of code.
Insert
Insert a new line of code before the currently selected line of code.
Delete
Deletes the currently selected line of code.
Tab Sheets - Create and Edit Program
DPE25601 Memory Available
With the created and edit program tab sheet selected, the user can obtain the amount of available
memory, located to the right of the Delete command button. The DPE25601 has a maximum
available memory of 2046 bytes - each instruction can use from 2 to 7 bytes.
Current Program Filename
With the create and edit program tab sheet selected, the user can obtain the current program
filename, located in the lower left corner of the SMC60WIN window. All programs created by the
SMC60WIN software will have a .mdb and a .bak extension.