32
Synthetic scouring pad
•
If the continuity of the circuit breaker is good (less than 0.1 Ohms), using the multimeter's ohmmeter
mode, check the continuity of the fuse between the positive terminal of the rear battery and the
"Anderson" connector.
•
If continuity of the fuse between the positive (+) terminal of the battery and the positive (+) terminal of
the "Anderson" connector is good (0.1 Ohms or less), check the continuity of the fuse that connects both
12-volt batteries using the multimeter's ohmmeter mode. If the ohmmeter shows a reading of O.L
(infinity), replace the cable with the built-in fuse. If the value is greater than 0.1 Ohms but less than O.L
(infinity), unscrew terminals of the fuse cable and clean the contacts as well as those of the battery using a
synthetic scouring pad. Do not use steel wool. Once the contacts are clean, reconnect the fuse and secure
bolts so that the fuse terminals cannot move at all. Check for continuity again. Replace the fuse if in doubt.
•
If after doing all previous steps, the voltage of the battery "Anderson" connector terminals is around 0 Volts,
check continuity between the fuse terminals connecting both 12 Volt batteries. The reading should be
0.1 Ohms or less. If the ohmmeter shows a value of O.L (infinity), replace the fuse, making sure that the
terminals of the new fuse are tight so that they cannot move at all. If the resistance value is greater than
0.1 Ohms but less than O.L. (Infinity), remove fuse bolts connecting both 12-volt batteries and clean
contacts using a fine or medium synthetic scouring pad. Do not use steel wool! Once contacts are clean,
reconnect the fuse and secure bolts so that the fuse terminals cannot move at all. Check for continuity
again. Replace the fuse if in doubt.