Appendix B: AMX Lighting Curves
45
AMX Lighting PROlink/AXlink Programming
FIG. 21 shows the output voltage of a RAD-MC120 dimmer. It has a smooth taper and a cut off
point of 25 volts. This curve will shrink incandescent dimming range 25%.
!
Relay turn on level = 1%
!
Dimming Range = 30 - 115 VAC.
FIG. 22 shows the output voltage of the RAD-VDR module. The voltage range is from 2.6 to 9.3
VDC when attached to test ballast. This curve is primarily used with Advance Mark VII ballast
using the RAD-VDR module.
FIG. 23 shows the output voltage of a RAD-MC120 dimmer. There is a noticeable gap at the low
end. Curve 4 is a smooth fade until 15%, then it rolls off sharply.
!
Relay turn on level = 1%
!
Dimming Range = 0 - 120 VAC.
FIG. 21
Curve 3 voltage output in volts RMS
FIG. 22
Curve 3 output in volts DC
FIG. 23
Curve 4 Voltage output in Volts RMS