Pre-Installation Settings
9
AMX Lighting PROlink/AXlink Programming
Connecting dry closures
Eight connections are available for dry contact closures and one common reference point. FIG. 8
shows the standard wiring configuration for the 9-pin dry closure connector.
Each contact closure connection (1 through 8) is pre-programmed with a default preset. The
following table shows the default presets for each contact closure.
Dry closure method to reset Default Settings
The default settings can be restored using the Dry Closure Input connection. By wiring all nine pins
(input pins 1-8, and the COM pin) together and plugging it into the Dry Closure port on a control
card for one minute will reset all default settings and parameters to the factory default settings as
listed previously.
To reset a AMX Lighting controller to default mode:
1.
Power Off the AMX Lighting controller at the circuit breaker panel.
FIG. 7
PROlink wiring diagram
FIG. 8
9-pin dry closure connector (standard configuration)
Default Dry-Closure Presets
Contact closure Default presets & functions
1
Preset 1, Channel 1 at 100% in 1 second*
2
Preset 2, Channel 2 at 100% in 1 second*
3
Preset 3, Channel 3 at 100% in 1 second*
4
Preset 4, Channel 4 at 100% in 1 second*
5
Preset 5, Channel 5 at 100% in 1 second*
6
Preset 6, Channel 6 at 100% in 1 second*
7
Preset 7, Channel 1 - 6 at 100% in 1 second*
8
Preset 8, Channel 1 - 6 at 0% in 1 second*
Panja Lighting PROlink connector
PRO-SP8 wall panel
+12V
PR-
PR+
GND
GND
PR+
PR-
+12V
C
O
M
1
9-pin dry closure
connector
2
3
4
5
6
7
8
Summary of Contents for ProLink PRO-DP8
Page 1: ...instruction manual Lighting Control AMX Lighting PROlink AXlink Programming ...
Page 4: ......
Page 8: ...iv AMX Lighting PROlink AXlink Programming Table of Contents ...
Page 14: ...Introduction 6 AMX Lighting PROlink AXlink Programming ...
Page 22: ...Pre Installation Settings 14 AMX Lighting PROlink AXlink Programming ...
Page 46: ...Appendix A PROlink vs AXlink Commands 38 AMX Lighting PROlink AXlink Programming ...
Page 65: ...Appendix C Troubleshooting 57 AMX Lighting PROlonl AXlink Programming ...