Pre-Installation Settings
12
AMX Lighting PROlink/AXlink Programming
Wiring Considerations
The following information relates to wiring considerations for a AMX Lighting system.
Preparing/connecting captive wires
1.
Strip 0.25 inch of wire insulation off all wires.
2.
Insert each wire into the appropriate opening on the connector according to the wiring
diagrams and connector types described in this section.
!
Do not tighten the screws excessively; doing so may strip the threads and damage the
connector.
Axcess Control - PC to Axcess Controller
The following table lists the pinout information for the DB-9 connector.
FIG. 10 shows a DB9 pinout relation from the computer to the Axcess Central Controller.
Use cable FG #10-727 to connect computer the COM port to Axcess or AXCENT Program Port.
Do not connect power to the device until the wiring is complete.
DB-9 Connector Pinouts
Pin Signal
Pin Signal
1
N/A
6
N/A
2
RXD
7
RTS
3
TXD
8
CTS
4
N/A
9
N/A
5
GND
FIG. 10
Computer to Axcess connection
Connection view
DB9 (9-Pin Female)
5 (GND)
3 (TXD)
2 (RXD)
5 (GND)
2 (RXD)
AXCENT
3
Pro Program Port
3 (TXD)
DB-9 (9-Pin Female)
Computer COM Port
Pin 1
Pin 6
Pin 5
Pin 9
Summary of Contents for ProLink PRO-DP8
Page 1: ...instruction manual Lighting Control AMX Lighting PROlink AXlink Programming ...
Page 4: ......
Page 8: ...iv AMX Lighting PROlink AXlink Programming Table of Contents ...
Page 14: ...Introduction 6 AMX Lighting PROlink AXlink Programming ...
Page 22: ...Pre Installation Settings 14 AMX Lighting PROlink AXlink Programming ...
Page 46: ...Appendix A PROlink vs AXlink Commands 38 AMX Lighting PROlink AXlink Programming ...
Page 65: ...Appendix C Troubleshooting 57 AMX Lighting PROlonl AXlink Programming ...