Installation & Setup
29
Precis HT Instruction Manual
Control Panel
To disconnect the factory default switch using the control panel:
1.
Press the Cancel Key to place the panel in Switch mode.
All the lights on the control panel turn off.
The control panel is in Switch mode.
2.
Press the All Level Key.
The All Level Key illuminates.
3.
Press Input Key 1.
Input Key 1 flashes.
After a moment all the Output Keys illuminate.
4.
Press each Output Key.
The Output Keys each disconnect (turn off) when pressed.
When executing a test switch, we suggest routing Input (source) 1 to Output (destination) 2 on
Level 0 (All VMs).
To execute a test switch using the control panel:
1.
Press the Cancel Key to place the panel in Switch mode.
2.
Press the All Level Key.
The All Level Key illuminates.
3.
Press Input Key 1.
Input Key 1 flashes.
4.
Press Output Key 2.
When Output Key 2 illuminates, the switch is successful.
Verify that the source signal is present (visible and/or audible) at the destination.
AMX Control Device
For executing and disconnecting switches using an AMX control device, see the specific control device
documentation.
APControl 3.0 or APWeb
Directions for executing and disconnecting switches using APControl 3.0 are found in its Help file.
For directions for executing switches using APWeb, see the
APWeb Instruction Manual
.
Cancel Key
All Level Key
Input Keys
Output Keys
FIG. 19
Precis HT 12x8 control panel
Summary of Contents for Precis HT
Page 1: ...Instruction Manual Matrix Switchers Precis HT Distribution Matrix Release 2 03 2009 ...
Page 4: ......
Page 12: ...Notices 6 Precis HT Instruction Manual ...
Page 38: ...Installation Setup 32 Precis HT Instruction Manual ...
Page 50: ...Control Panel Operation 44 Precis HT Instruction Manual ...
Page 60: ...Appendix A Managing Configuration Files 54 Precis HT Instruction Manual ...
Page 64: ...Appendix B Advanced Configuration Modifying Virtual Matrices 58 Precis HT Instruction Manual ...