background image

 

 

 

IPES-5208T-X, IPES-5208T 

IPES/IES-5208DF Series 

8 10/100TX D-coded + 2 10/100/1000T (X-coded) or 2 100/1000 FX 

L2

+

 (w/8 PoE at/af) Industrial Managed Switch w/Enhanced G.8032 

Ring

 

 

User Manual (Hardware) 

 

 

                                                                   

 

 

 

 

 

                                                                   

 

 

   

 

Sept.  2017 

Summary of Contents for IPES-5208T-X Series

Page 1: ...PES 5208T X IPES 5208T IPES IES 5208DF Series 8 10 100TX D coded 2 10 100 1000T X coded or 2 100 1000 FX L2 w 8 PoE at af Industrial Managed Switch w Enhanced G 8032 Ring User Manual Hardware Sept 201...

Page 2: ...y an STP network cable in demanding electrical environments Examples of demanding indoor environments are where the network cable is located in parallel with electrical mains supply cables or where la...

Page 3: ...consent of Lantech Communications Global Inc Products offered may contain software which is proprietary to Lantech Communications Global Inc The offer or supply of these products and services does no...

Page 4: ...occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encourage...

Page 5: ...ent 22 2 3 IP Protection 22 2 4 LED Indicators 25 Chapter 3 Hardware Installation 27 Chapter 4 Network Application 33 4 1 ITU G 8032 Scheme 33 4 2 Ring Coupling 33 4 3 Multiple Rings 34 4 4 Dual Homin...

Page 6: ...witch w Enhanced G 8032 Ring Specification IPES 5208T X 43 Standards IEEE 802 3 10Base T Ethernet IEEE 802 3u 100Base TX IEEE802 3z Gigabit fiber IEEE802 3x Flow Control and Back Pressure IEEE802 3ad...

Page 7: ...Cable 10Base T 2 pair UTP STP Cat 3 4 5 5E 6 cable EIA TIA 568 100 ohm 100m 100Base TX 2 pair UTP STP Cat 5 5E 6 cable EIA TIA 568 100 ohm 100m 1000Base TX 2 pair UTP STP Cat 5 5E 6 cable EIA TIA 568...

Page 8: ...Max 13W 12V 48VDC input Max 16W 72 110VDC input Case Dimension IP43 model Aluminum case 203mm W x187mm H x84 4mm D Weight 1 0kgs Installation DIN Rail and Wall Mount Design EMI EMS FCC Class A CE EN55...

Page 9: ...Radius IEEE802 1p Class of Service IEEE802 1Q VLAN Tag IEEE802 3at af Power over Ethernet Switch Architecture Back plane Switching Fabric 9 6Gbps Packet throughput ability Full Duplex 23 8Mpps 64bytes...

Page 10: ...P Fail Red Ethernet port Link Activity Green Speed Green DI DO 1 Digital Input DI Level 0 30 2V Level 1 10 30V Max input current 8mA 1 Digital Output DO Open collector to 40 VDC 200mA Operating Humid...

Page 11: ...rs Verifications report EN50155 EN50121 3 2 EN50121 4 verification EN45545 2 R24 R25 EN ISO 4589 2 EN ISO 5659 2 NF X70 100 1 2 Fire Smoke verification Warranty 5 years Future release Optional IPES 52...

Page 12: ...or single mode or multi mode type fiber cable RS 232 connector 1 x M12 5 pole A coded Power Input connector 1 x M23 5 pole A coded Relay contact 1 x M12 5 pole A coded Network Cable 10Base T 2 pair UT...

Page 13: ...C 40 F 185 F Power Supply 45 56VDC on standard model 9 5 56VDC on 12V model 50 4 90VDC on 72V model 43 137 5VDC on 110V model with input isolation PoE Budget 240W for 45 56V input 55V input is recomme...

Page 14: ...ISO 5659 2 NF X70 100 1 2 Fire Smoke verification Warranty 5 years Future release Optional IES 5208DF Series Standards IEEE 802 3 10Base T Ethernet IEEE 802 3u 100Base TX IEEE802 3z Gigabit fiber IEEE...

Page 15: ...le A coded Network Cable 10Base T 2 pair UTP STP Cat 3 4 5 5E 6 cable EIA TIA 568 100 ohm 100m 100Base TX 2 pair UTP STP Cat 5 5E 6 cable EIA TIA 568 100 ohm 100m 1000Base TX 2 pair UTP STP Cat 5 5E 6...

Page 16: ...2V 48VDC input Max 16W 72VDC 110VDC input Case Dimension IP67 model Aluminum case 215mm W x200mm H x84 4mm D IP43 model Aluminum case 203mm W x187mm H x84 4mm D Weight 1 4kgs IP67 1 2kgs IP43 Installa...

Page 17: ...16 Optional...

Page 18: ...the Industrial switch s hardware spec port cabling information and wiring installation 2 1 Physical Dimension IPES 5208T X 43 Aluminum case IP 43 203mm W x187mm H x84 4mm D IPES 5208T 43 Aluminum case...

Page 19: ...18 215mm W x200mm H x84 4mm D IPES 5208DF 43 Aluminum case IP 43 203mm W x187mm H x84 4mm D IES 5208DF 67 Aluminum case IP 67 215mm W x200mm H x84 4mm D...

Page 20: ...19 IES 5208DF 43 Aluminum case IP 43 203mm W x187mm H x84 4mm D...

Page 21: ...20 Port description of IPES 5208T X...

Page 22: ...21 Port description of I P ES 5208DF...

Page 23: ...ingers dust accidental contact and water in mechanical casings and with electrical enclosures It is published by the International Electrotechnical Commission IEC Solid particle protection The first d...

Page 24: ...ingress of dust complete protection against contact Liquid ingress protection The second digit indicates the level of protection that the enclosure provides against harmful ingress of water Level Pro...

Page 25: ...ance of 3 m 6 Powerful water jets Water projected in powerful jets 12 5 mm nozzle against the enclosure from any direction shall have no harmful effects Test duration at least 3 minutes Water volume 1...

Page 26: ...downs 2 4 LED Indicators The diagnostic LEDs that provide real time information of system and optional status are located on the front panel of the industrial switch The following table provides the d...

Page 27: ...eiving packets from the TX device Off No device attached PoE 1 8 IP ES On The port is operating in PoE mode IPES Off The port is not operating in PoE mode IPES P9 P10 Link Ack On A network device is d...

Page 28: ...8T IPES 5208DF is connected via a 5 pole M23 female connector while IES 5208DF is with a 5 pole M12 female connector Voltage of Power Input Non PoE model Standard model The power input voltage can be...

Page 29: ...devices Please make sure that the external power supply unit you use to provide the PoE voltage meet the following criteria The output voltage of power supply must exceed 48VDC for 802 3af and 53VDC f...

Page 30: ...larm relay A break in contact is reported via the relay contact The failure of at least one of the two supply voltages The break link status of at least one switch port 3 1 4 Fitting the device ground...

Page 31: ...30 Ground screw 3 1 5 Connect the M12 connector with RJ 45 data cable ports are not used shall be caped that comes with the package to insulate the surrounding...

Page 32: ...31 Pin assignment of M12 10 100Tx network connector Pin assignment of M12 10 100 1000T network connector...

Page 33: ...us Note The protection class IP67 is only achieved when bolted together The other components attaching to the system have to meet with the IP67 protection class in order to reach the whole system IP67...

Page 34: ...munication Unit G 8032 v2 draft The benefits of G 8032 are 1 50ms recovery time when failover 2 G 8032 has defined the protocol scheme parameters functions test measures to be unified that the users c...

Page 35: ...34 4 3 Multiple Rings...

Page 36: ...35 4 4 Dual Homing 4 5 Chain...

Page 37: ...36...

Page 38: ...r to the console port of the switch The connected terminal or PC must support the terminal emulation program 5 2 Login in the Console Interface When the connection between Switch and PC is ready turn...

Page 39: ...t appears Key in admin default value for both User name and Password use Enter key to switch then press Enter and the Main Menu of console management appears Please see below figure for login screen C...

Reviews: