WARNING:

 The maximum recommended torque to screw in the locking tabs on the 

plastic back box is 105 IN-OZ [74 N-CM]. Applying excessive torque while tightening 
the tab screws, such as with powered screwdrivers, can strip out the locking tabs or 
damage the plastic back box.

1.

Prepare the area by removing any screws or nails from the drywall before 
beginning the cutout process.

2.

Cut out the surface for the back box. Refer to the dimensions in the 

NXCD-500i 

User Manual

, available from 

www.amx.com

, for more information.

CAUTION:

 Making sure that the actual cutout opening be slightly smaller than the 

provided dimensions is highly recommended. This action provides the installer with a 
margin for error if the opening needs to be expanded. Too little wall material removed 
is always better than too much.

3.

Remove the bezel from the NXD-435.

4.

Disconnect the capacitive touch connector from the 10-pin plug on the 

 

bezel.

5.

Insert both connectors into their corresponding locations along the bottom of 
the NXD-435 touch panel.

6.

Test the incoming wiring by attaching the panel connections to their terminal 
locations and applying power via the PoE Injector. Verify that the panel is 
receiving power and functioning properly to prevent repetition of the 
installation.

7.

Thread the incoming Ethernet and mini-USB wiring (if mini-USB access is 
desired) from their terminal locations through the surface opening. 

Leave 

enough slack in the wiring to accommodate any re-positioning of the panel.

8.

Push the back box into the wall opening. Insure that the locking tabs lie flush 
against the back box.

9.

Extend the locking tabs on the sides of the back box by tightening the screws 
inside the box until snug. Not all of the tabs must be extended to lock the back 
box in place, but extending a minimum of two tabs is highly recommended. 
Apply enough pressure to the screw head to keep the box flush with the wall: 
this ensures that the locking tabs will tighten up against the inside of the wall. 

 

The back box is clear to allow visual confirmation that the tabs have been 
extended and are gripping the wall, as well as in assisting with removal if 
necessary.

NOTE:

 Do not disconnect the connectors from the touch panel. The unit must be 

installed with the attached connectors before being inserted into the drywall.

10.

Carefully replace the two Plastite screws holding the device to the back box.

11.

Reconnect the capacitive touch connector to the 10-pin plug on the bezel.

12.

Place the bezel back onto the device.

13.

Reconnect the terminal Ethernet and USB to their respective locations on 
either the Ethernet port or NetLinx Master.

Installing the NXD-435 into a Flat Surface using #4 screws

Three #4 mounting screws (not included) are secured through circular holes located 
at the left and right sides of the NXD-435. The most important thing to remember 
when mounting the NXD-435 is that the outer frame (Mounting Tabs) must be 
installed flush against the mounting surface.

Refer to SP-2262-02 for detailed installation dimensions.

Cutting out the surface slightly smaller than what is outlined in the installation 

drawings in order to make any necessary cutout adjustments, is highly 
recommended.

1.

Prepare the area by removing any screws or nails from the surface before 
beginning the cutout process.

2.

Cut out the surface for the NXD-435.

3.

Remove the bezel from the NXD-435.

4.

Disconnect the capacitive touch connector from the 10-pin plug on the 

 

faceplate.

5.

Thread the incoming Ethernet and USB wiring from their terminal sources 
through the surface opening. Leave enough slack in the wiring to 
accommodate any re-positioning of the panel.

6.

Connect the Ethernet and USB connectors to their corresponding locations 
along the bottom of the un-powered NXD-435 touch panel. The USB 
connectors can be from either a USB extension cable or a wireless USB RF 
transmitter.

NOTE: 

Do not disconnect the connectors from the touch panel. The unit must be 

installed with the necessary connectors before being inserted into the solid surface. 

7.

Carefully slide the main unit into the cutout until the Mounting Tabs of the 
NXD-435 lie flush against the wall.

8.

Insert and secure three #4 Mounting Screws (not included) into the 
corresponding holes located along the sides of the NXD-435, using a grounded 
Phillips-head screwdriver, until the unit is secure and flush against the wall.

9.

Reconnect the capacitive touch connector to the 10-pin plug on the faceplate.

10.

Place the bezel back onto the device.

11.

Reconnect the terminal Ethernet and USB to their respective locations on 
either the Ethernet port or NetLinx Master.