Making the Cables 

Use Category 5 (CAT-5) wire for all PhastLink connections. CAT-5 wire consists of 
4 twisted pairs of wires. An RJ-45 connector is used at each end. 

T568A Wiring Standard (PhastLink Cables) 

The cables between the PMB-RF, PMB-TCC, and PMB-CF2 are CAT-5 PhastLink 
cables. These cables use the T568A wiring standard for the RJ-45 pin connections at 
BOTH ends of each cable. These connections are shown in Figure 8: 

CAT-5 PhastLink cables (T568A Wiring Standard) 

Pin 

Wire 

PIN1 

White/Green 

PIN2 

Green 

PIN3 

White/Orange 

PIN4 

Blue 

PIN5 

White/Blue 

PIN6 

Orange 

PIN7 

White/Brown 

PIN8 

Brown 

T568A-to-T568B Wiring Standard (NULL 10-BaseT Ethernet Cable) 

The cable between a computer's Ethernet card and the PLC-MCU card (in the PMB-
CF2) is a CAT-5 10-BaseT Ethernet cable that uses the T568A standard at one end of 
the cable and the T568B wiring standard at the other end of the cable. It does not 
matter which end is plugged into which device, as long as one end is wired one 
way and the other end is wired the other way. 

NULL 10-BaseT Ethernet Cable (T568A to T568B Wiring Standard) 

Connections at One End (T568A) 

Connections at the Other End (T568B) 

PIN1 

White/Green 

PIN1 

White/Orange 

PIN2 

Green 

PIN2 

Orange 

PIN3 

White/Orange 

PIN3 

White/Green 

PIN4 

Blue 

PIN4 

Blue 

PIN5 

White/Blue 

PIN5 

White/blue 

PIN6 

Orange 

PIN6 

Green 

PIN7 

White/Brown 

PIN7 

White/Brown 

PIN8 

Brown 

PIN8 

Brown 

Important! 

There are TWO different 

wiring standards used in a 

Landmark Cinema system. 

Depending on what devices 

are being connected, you 

must select the proper 

standard, as explained below. 

Figure 8 

CAT-5 PhastLink cable 

connections at both ends 

(T568A wiring standards) 

Note 

If you are connecting the 

PLC-MCU card to an Ethernet 

hub instead of to an Ethernet 

card in a PC, use a straight-

through, pin-to-pin cable. 

Figure 9 

NULL 10-BaseT Ethernet 

Cable (T568A to T568B 

Wiring Standard) 

Summary of Contents for Landmark Cinema

Page 1: ...instruction manual Landmark Products Landmark Cinema...

Page 2: ...ird party or made by you for a third party This limitation of liability applies whether damages are sought or a claim is made under this warranty or as a tort claim including negligence and strict pro...

Page 3: ...onents 2 PMB CF2 Mini Cardframe 2 PMB TCC Television Control Center 3 PMB RF RF Receiver 4 Viewpoint Wireless Touch Panels 5 Computer 6 Selecting Audio and Video Devices 6 Placing the Devices 7 Mappin...

Page 4: ...ii Table of Contents Landmark Cinema Quick Setup Guide...

Page 5: ...and video switching for the theater system Landmark Cinema controls this device via an IR emitter Up to seven additional IR controlled devices can be controlled by a Landmark Cinema system This docum...

Page 6: ...card used in the Landmark Cinema package is the PLC IROUT IR Output card Connection to the other Landmark Cinema components except for the Viewpoint Touchpanel is via a PhastLink cable that plugs int...

Page 7: ...will blink on and off in equal 1 2 second intervals The green LED on the PLC IROUT card will only blink when sending an IR signal out from the card PMB TCC Television Control Center The PMB TCC has fo...

Page 8: ...Viewpoint Touchpanel allowing omni directional control from up to 100 feet away Connection to the PMB CF2 is via a PhastLink cable that plugs into a PhastLink RJ 45 port on the rear of the unit Figure...

Page 9: ...be quickly and easily custom tailored for any client s needs with many possible menu levels and screens The unit is designed to function as either a desktop or hand held remote control The Viewpoint c...

Page 10: ...to the PLC MCU card the computer may be disconnected from the Landmark Cinema system and the program will run from the PLC MCU card If programming changes are to be made the computer must be reconnec...

Page 11: ...ocated This may have an effect for example on which IR output ports you select to control specific system devices It will also determine your wiring and cabling needs When placing devices allow access...

Page 12: ...r cable map out which IR output ports will be used to control the various IR controlled devices in the system and note the PhastLink cabling requirements Figure 7 will help you map the wiring to the I...

Page 13: ...Landmark Cinema Quick Setup Guide Introduction 9 Figure 7 Mapping the wiring to the IR emitters...

Page 14: ...one end of the cable and the T568B wiring standard at the other end of the cable It does not matter which end is plugged into which device as long as one end is wired one way and the other end is wir...

Page 15: ...Landmark Cinema Quick Setup Guide Introduction 11...

Page 16: ...k 3000 research drive richardson TX 75082 USA 469 624 8000 800 222 0193 fax 469 624 7153 technical support 800 932 6993 051 004 2439 8 01 2001 AMX Corporation All rights reserved AMX the AMX logo the...

Reviews: