Using FileTransfer2
21
FileTransfer2
7.
Click
OK
to save the new Modem communication settings with the selected file.
Configuring Virtual NetLinx Master Communication Settings (NetLinx only)
1.
Click the
Edit
command button, and select Communication Settings to open the
Communication Settings dialog.
2.
Select
NetLinx Master
as the Platform Selection.
3.
Select
Virtual NetLinx Master
as the Transport Connection Option.
4.
Click
Edit Settings
to access the Virtual NetLinx Master Settings dialog, which displays the
System number (and IP address) of the Virtual NetLinx Master (
default = 1
).
Assuming that the actual NetLinx Master is set to
0
(via the System Properties dialog - System
ID field), this default setting will work. However, if you have designated any other number as
the System ID, be sure to set this System Number to a different number than the System ID, to
avoid a conflict with the actual NetLinx Master (range =
1-65535
).
5.
Click
OK
to return to the Communication Settings dialog.
6.
Click
OK
to save the new VNM communication settings with the selected file.
Configuring the Touch Panel for Virtual NetLinx Master USB Transfers
If it is not already powered up and connected, apply power to the G4 panel and verify that it is
connected to the PC running NetLinx Studio via the USB connector on the rear (or side) of the
panel.
Connecting the Panel to your PC via USB:
1.
Apply power to the panel by plugging in the power supply.
2.
Wait for the splash screen to disappear, then use a (Type A) USB cable to connect the panel to
an available USB port on your PC. Plug the USB cable into the panel first, then connect to the
PC.
To configure the panel for Virtual NetLinx Master transfers via USB:
1.
Press and hold the grey Front Setup Access button (below the touch screen) for 3 seconds to
access the Setup page.
2.
Press the
Protected Setup
button to access the Protected Setup page.
3.
Use the on-screen keyboard to enter the password (the default password is
1988
).
4.
Press the
System Connection
button to access the System Connection Setup page.
5.
Select
USB
as the Master Connection.
6.
Press the
Back
button to return to the Protected Setup page and press the
Reboot
button to
reboot the panel.
As indicated in the Virtual NetLinx Master dialog, changes made to the system
number field will not take effect until all communications are stopped and restarted.