44
DUX-12F
USER MANUAL
IDX
Function
Command
Example
11
To verify a sink
power control
status
Command:
SL#O#SPAT
Return:
SL#O#SPAT( value )
Description:
L#: #={0, 1} or “L” is omitted
O#: # = {1~4};
value = {0, 1} // {0, 1}:{off, on}
Command:
SO3SPAT
Return:
SO3SPAT( 1 )
Description:
Output 3 is in cec auto control
12
To define a Delay
Time to power off
a sink when no
active signal
Command:
CL#O#D#SPT
Return:
CL#O#D#SPT
Description:
L#: #={0, 1} or “L” is omitted
O#: # = {1~4};
D# : # = {1, …30}
Command:
CO1D2SPT
Return:
CO1D2SPT
Description:
Define Delay Time of 2 minutes to power off
the sink connected to Output 1 when no active
signal
13
To verify Delay
Time of powering
off a sink when
no active signal
Command:
SL#O#DSPT
Return:
SL#O#DSPT( value )
Description:
L#: #={0, 1} or “L” is omitted
O#: # = {1~4};
value = {1, …30}
Command:
SO3DSPT
Return:
SO3DSPT( 2 )
Description:
Delay Time of CEC Auto Control is 2 min.
14
To verify EDID
Dip Status
Command:
SL#DIPT
Return:
SL#DIPT( value )
Description:
L#: #={0, 1} or “L” is omitted;
value = {0, …15}
{
0 : EDID controlled by Web UI and API
1 : 4K@60Hz 4:4:4 8bit 5.1ch audio
2 : 4K@60Hz 4:4:4 8bit 2.0ch audio
3 : 4K@30Hz 4:4:4 8bit 5.1ch audio
4 : 4K@30Hz 4:4:4 8bit 2.0ch audio
5 : 1080p@60Hz 4:4:4 8bit 5.1ch audio
6 : 1080p@60Hz 4:4:4 8bit 2.0ch audio
7...15 : Customize,
};
Command:
SDIPT
Return:
SDIPT( 0 )
Description:
The EDID Dip status is 0, i.e. the EDID setting
can be controlled by Web UI and API.