IMPORTANT SAFETY INSTRUCTIONS

a

Tango Zone Expanders

IMPORTANT SAFETY INSTRUCTIONS

1.

Read instructions.

2.

Keep these instructions.

3.

Heed all warnings.

4.

Follow all instructions.

5.

Do not use this apparatus near water.

6.

Clean only with dry cloth.

7.

Do not block any ventilation openings. Install in accordance with the manufacturer’s 
instructions.

8.

Do not install near any heat sources such as radiators, heat registers, stoves, or other 
apparatus (including amplifiers) that produce heat.

9.

Do not defeat the safety purpose of the grounding-type plug. The grounding plug has two 
blades and a third grounding prong. The third prong is provided for your safety. If the provided 
plug does not fit into your outlet, consult an electrician for replacement of the obsolete outlet.

10.

Protect the power cord from being walked on or pinched particularly at plugs, convenience 
receptacles, and the point where they exit from the apparatus.

11.

Only use attachments/accessories specified by the manufacturer.

12.

Use only with cart, stand, tripod, bracket, or table specified by the manufacturer, or sold with the 
apparatus. When a cart is used, use caution when moving the cart/apparatus combination to 
avoid injury from tip-over.

13.

Unplug this apparatus during lightning storms or when unused for long periods of time.

14.

Refer all servicing to qualified personnel. Servicing is required when the apparatus has been 
damaged in any way, such as power supply cord or plug is damaged, liquid has been spilled or 
objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, 
does not operate normally, or has been dropped.

Warning: Shock Hazard

 - The lightning flash within an equilateral triangle, intended to 

alert the user to the presence of un-insulated “Dangerous voltage” within the products 
enclosure that may be of significant magnitude to constitute a risk of electric shock to 
persons

Read Accompanying Documentation

 – The exclamation point within an equilateral 

triangle is intended to alert the user to the presence of important operating and 
maintenance (servicing) instructions in the literature accompanying the product.

15.

The fuse should only be replaced with a T8AL250V fuse.

16.

The RCA, RJ11and RJ45 Jacks shall only be used for their intended use. Refer to 
accompanying documentation to insure that they are being used as intended.

17.

The spring clip terminals and F-connector on the tuner module should only be used to connect 
an AM and FM antenna.

18.

A grounded power outlet is required for safe operation.

19.

The grounded 3 prong power cable will be the mains disconnect and it should remain readily 
available.

20.

To completely disconnect the unit from the AC mains, disconnect the power supply cord plug 
from the AC receptacle.

21.

The main voltage for the AC mains is 120v AC

Warning

 – To reduce the risk of fire or electric shock, do not expose this apparatus to rain or 

moisture. Do not expose this equipment to dripping or splashing and ensure that no objects filled 
with liquids are placed on the equipment.

Summary of Contents for DAS-T0804X-SIG

Page 1: ...Operation Reference Guide Tango Distributed Audio Tango Zone Expanders DAS T0804X SIG DAS T0808X SIG Initial Release 7 02 2008 ...

Page 2: ...rked on the outside of each box The RMA is valid for a 30 day period After the 30 day period the RMA will be cancelled Any shipments received not consistent with the RMA or after the RMA is cancelled will be refused AMX is not responsible for products returned without a valid RMA number AMX is not liable for any damages caused by its products or for the failure of its products to perform This incl...

Page 3: ... such as power supply cord or plug is damaged liquid has been spilled or objects have fallen into the apparatus the apparatus has been exposed to rain or moisture does not operate normally or has been dropped Warning Shock Hazard The lightning flash within an equilateral triangle intended to alert the user to the presence of un insulated Dangerous voltage within the products enclosure that may be ...

Page 4: ...IMPORTANT SAFETY INSTRUCTIONS b Tango Zone Expanders ...

Page 5: ...ing and Connections 3 Speaker Wire Technology SWT 3 Front and Rear Panel Components 4 Cabling Instructions 4 Cable Type 4 Connecting Sources Audio Inputs Outputs 5 Connecting Zone Outputs 5 SWT Connectors 5 Connecting Paging Inputs Outputs 6 Connecting To Tango Audio Controllers 6 Zone Expander Addressing 9 Overview 9 DAS T0808 SIG 8 Zone Audio Controller 9 DAS T0804 SIG 4 Zone Audio Controller 9 ...

Page 6: ...ii Tango Zone Expanders Table of Contents ...

Page 7: ...W Audio Inputs Stereo 47K impedance DAS T0804X SIG 4 Stereo Inputs DAS T0808X SIG 8 Stereo Inputs Audio Outputs DAS T0804X SIG 4 Stereo Looping Outputs DAS T0808X SIG 8 Stereo Looping Outputs Zones 4 or 8 Independent Zones 4 X 2 Zone Modules Front Panel Components Light Bar Blue light bar indicates power status LEDs Blue LEDs illuminate function buttons Rear Panel Components Power Switch Receptacl...

Page 8: ...ections for up to 8 zone outputs that connect to the keypads Audio Inputs Stereo Inputs 47K impedance buffered Audio Outputs Stereo Looping Outputs buffered Available Colors black silver Dimensions HWD 17 x 3 5 x 13 5 43 18cm x 8 89cm x 34 29cm including feet and connectors Shipping Weight 8 27 95 lbs 12 68 kg ...

Page 9: ...nology removes the need for control wire since the control and audio signals are shared on the same wire The reliability and simplicity of this system has been proven for years AMX Matrix Audio is the only company that offers a retrofit solution one which allows the replacement of volume controls with AMX Matrix Audio keypads and Controllers giving full control over the sources Additionally the ve...

Page 10: ...ctor speaker cable originating at the Tango Controller passing through the Keypad and terminating at the speaker location AMX recommends using a bundled 4 conductor 16 gauge stranded copper wire in a single continuous run FIG 1 Tango Amplifiers DAS TAMP4 SIG shown Expansion Port IN from Tango Audio Controller Expansion Port OUT Address Switch Zone Outputs up to 8 Paging IN OUT Stereo Inputs Output...

Page 11: ...ovide basic transport control source selection and volume up and down as well as enhanced controls including direct access capability favorite s source selection zone grouping alarm clock setting and Keypad lockout SWT Connectors SWT cabling follows a specific pinout configuration that is labelled on the Tango Controller Metreau keypads and other Matrix devices as shown in FIG 3 FIG 2 Connecting S...

Page 12: ... connections between the Tango Audio Controller and multiple Tango Zone Expanders FIG 4 Connecting Paging Input Outputs FIG 5 Connecting the Tango Controller to Zone Expanders Tango Audio Controller Tango Zone Expander 1 Paging Out Paging In From phone system or Paging Out Paging In To Paging In connector on Tango Zone Expander 2 communication box Tango Audio Controller Tango Zone Expander 1 Tango...

Page 13: ...rride is used connect the paging output loop from the Tango Controller to the Zone Expander see FIG 5 5 Connect the keypads to the Tango Controller and Zone Expander s Following the same wiring code you used at each of the keypad locations plug each SWT connector into the desired Zone Output connectors on the Tango Controller and Zone Expanders see FIG 5 6 SWT Speakers connect to the Tango Control...

Page 14: ...Installation 8 Tango Zone Expanders ...

Page 15: ...17 20 set to Address 3 Zones 25 32 set to Address 3 Zone Expander 4 Zones 21 24 set to Address 4 Zones 33 40 set to Address 4 Zone Expander 5 Zones 25 28 set to Address 5 Zones 41 48 set to Address 5 Zone Expander 6 Zones 29 32 set to Address 6 Zones 49 56 set to Address 6 Zone Expander 7 Zones 33 36 set to Address 7 Zones 57 64 set to Address 7 Zone Expander Addressing Connected to DAS T0804 SIG ...

Page 16: ...registered trademarks of AMX AMX reserves the right to alter specifications without notice at any time It s Your World Take Control 3000 RESEARCH DRIVE RICHARDSON TX 75082 USA 800 222 0193 469 624 8000 469 624 7153 fax 800 932 6993 technical support www amx com ...