6. Ener-G-NET

 Control Setup & Adjustment

-7-

Ener-G-NET features two distinct programming areas: 

User Modes 

and

 

Installer Settings

User Modes

 consist of three end-user functional 

modes, while 

Installer Settings

 are primarily accessed upon initial setup 

to specify critical operating parameters. Ener-G-NET factory defaults 

allow traditional operation suitable for most homes. To optimize the 

control setup, reference the tables below.

Temperature settings above 120° F can create a 

scald hazard.

Mode 

Indicators

User 

Modes

Installer 

Settings

LED 

Display

User Mode

Code

Description

Standard

Efficiency

Vacation

On-Demand sensing reduces fuel consumption by limiting boiler operation during idle periods.

Traditional operation within preset temperature differential using a low and high limit.

Reduced temperature setting minimizes boiler operation during anticipaated periods of non-use.

User Modes

 are used to select from three distinct operational modes.  To select, press the green 

MODE

 button and press again to cycle through the three 

available modes.  A green dot illuminates to display the current mode.

Setting

Code

Description

Range

Temperature

Domestic hot water setpoint.  Default is 120°F

90-150

Differential

Domestic hot water temperature drop before call for heat.  Default is 10°F.

5,10*

Post-Purge

Early boiler shutoff prior to hot water setpoint. Circulator runs until setpoint. Default is 0°F.

0,4,8**

Priority

Temporarily cancels space heat to maxmize available energy for hot water. Default is 'n'.

y/n

Capacity

Water heater capacity; select appropriate size for proper operation.  Default is 41 Gallons.

26,41,60,80,120

BTU Transfer

Real-time BTU transfer estimate in 1000 BTU/Hr increments.  Diagnostic readout only.

0-199MBH/Hr

*Available in Standard Mode only.

**Available only when Differential setting is 10.

Installer Settings

 are used to adjust functional operating parameters.  To adjust, press and hold the 

SET

 button until the Temperature setting appears.  

Cycle through settings by depressing the 

SET

 button and using the 

 and ▲ buttons to change the settings.

Indicator

Code

Description

Startup Test

Idle

Heating

Displayed briefly during intial powerup to test LED display segments.

Operating Indicators

 are used

 

to

 

display operational and functional status. Water sensor temperature may be shown for 30 seconds by pressing 

the ▲ button.

Static numeric 

[setpoint]

 readout (factory default shown) indicates domestic hot water setpoint.

Alternating 

On

 and 

[Setpoint]

 is displayed during a heating cycle while the circulator pump contacts are closed.

Error

Code

Description

Potential Causes***

Temp Sensor

Temperature sensor (thermistor) fault.

Sensor unplugged

Sensor damaged

Overheating

Domestic hot water temperature has exceeded maximum setpoint.

Error in boiler plumbing

Zone valve stuck open

Leak in sensor well

Slow Heating

Unit has taken over 60 minutes to reach hot water setpoint or cannot reach setpoint.

Faulty equipment

Fouled heat exchanger

No fuel

***See Troubleshooting section for additional information

Diagnostic Error Codes

 display a visual indicator and sound an alarm if a fault is detected.  Codes clear automatically when corrected or can be reset by 

interrupting power to the control for 5 seconds. To silence an alarm, depress the ▼ on the keypad.

Summary of Contents for HYDROMAX HM-41

Page 1: ...The heat transfer medium must be water or other nontoxic fluid having a toxicity rating or class of 1 as listed in Clinical Toxicology of Commercial Products 5th edition The pressure of the heat trans...

Page 2: ...t the same time the water heater may not be supplied with enough hot boiler water to recover adequately The delivery of domestic hot water will be diminished In many but not all cases this is not a pr...

Page 3: ...etaining Screws 2 Heat Trap Boiler Supply Hot Water Outlet 15 10 5 0 0 2 4 6 8 Head Loss Feet Flow Gallons Per Minute HYDROMAX Components Single Wall Shown Two Piece Cover Removal and Installation Hea...

Page 4: ...rwise penetrate the steel outer tank shell Do not screw pipe hangers or other hardware into the exterior of the tank BOILER PIPING 1 Plumb the circulator or zone valve on the BOILER SUPPLY line 2 Pipe...

Page 5: ...duit metal clad cable or raceways Power Limited Circuit Cable needed not be provided with the protection specified above if it is securely fastened to the appliance jacket and follows the contour of t...

Page 6: ...B C1 C2 L2 ORANGE ORANGE WHITE BLACK BLUE BLUE VIOLET VIOLET POWER BURNER PUMP PRIORITY HYDROMAX CIRCULATOR HEATING CIRCULATOR L1 B B2 Z W C1 C2 L2 Millivolt HYDROMAX CIRCULATOR HEATING CIRCULATOR ORA...

Page 7: ...capacity select appropriate size for proper operation Default is 41 Gallons 26 41 60 80 120 BTU Transfer Real time BTU transfer estimate in 1000 BTU Hr increments Diagnostic readout only 0 199MBH Hr A...

Page 8: ...l Gas Valves Non Priority AQUASTAT ZONE VALVE MOTOR 24VAC END SWITCH TRANSFORMER L1 L2 4 Wire AQUASTAT Boiler Control Input HYDROMAX CIRCULATOR OR ZONE VALVE DHW ZONE Boiler Controls Zone Valves Unive...

Page 9: ...faucet 1 Poor water quality 2 Sediment or suspended particles 1 Have water tested for contaminants 2 Install sediment filter purge unit more often to avoid future problems Boiler will not operate whe...