6. Ener-G-NET
™
Control Setup & Adjustment
-7-
Ener-G-NET features two distinct programming areas:
User Modes
and
Installer Settings
.
User Modes
consist of three end-user functional
modes, while
Installer Settings
are primarily accessed upon initial setup
to specify critical operating parameters. Ener-G-NET factory defaults
allow traditional operation suitable for most homes. To optimize the
control setup, reference the tables below.
Temperature settings above 120° F can create a
scald hazard.
Mode
Indicators
User
Modes
Installer
Settings
LED
Display
User Mode
Code
Description
Standard
Efficiency
Vacation
On-Demand sensing reduces fuel consumption by limiting boiler operation during idle periods.
Traditional operation within preset temperature differential using a low and high limit.
Reduced temperature setting minimizes boiler operation during anticipaated periods of non-use.
User Modes
are used to select from three distinct operational modes. To select, press the green
MODE
button and press again to cycle through the three
available modes. A green dot illuminates to display the current mode.
Setting
Code
Description
Range
Temperature
Domestic hot water setpoint. Default is 120°F
90-150
Differential
Domestic hot water temperature drop before call for heat. Default is 10°F.
5,10*
Post-Purge
Early boiler shutoff prior to hot water setpoint. Circulator runs until setpoint. Default is 0°F.
0,4,8**
Priority
Temporarily cancels space heat to maxmize available energy for hot water. Default is 'n'.
y/n
Capacity
Water heater capacity; select appropriate size for proper operation. Default is 41 Gallons.
26,41,60,80,120
BTU Transfer
Real-time BTU transfer estimate in 1000 BTU/Hr increments. Diagnostic readout only.
0-199MBH/Hr
*Available in Standard Mode only.
**Available only when Differential setting is 10.
Installer Settings
are used to adjust functional operating parameters. To adjust, press and hold the
SET
button until the Temperature setting appears.
Cycle through settings by depressing the
SET
button and using the
▼
and ▲ buttons to change the settings.
Indicator
Code
Description
Startup Test
Idle
Heating
Displayed briefly during intial powerup to test LED display segments.
Operating Indicators
are used
to
display operational and functional status. Water sensor temperature may be shown for 30 seconds by pressing
the ▲ button.
Static numeric
[setpoint]
readout (factory default shown) indicates domestic hot water setpoint.
Alternating
On
and
[Setpoint]
is displayed during a heating cycle while the circulator pump contacts are closed.
Error
Code
Description
Potential Causes***
Temp Sensor
Temperature sensor (thermistor) fault.
Sensor unplugged
Sensor damaged
Overheating
Domestic hot water temperature has exceeded maximum setpoint.
Error in boiler plumbing
Zone valve stuck open
Leak in sensor well
Slow Heating
Unit has taken over 60 minutes to reach hot water setpoint or cannot reach setpoint.
Faulty equipment
Fouled heat exchanger
No fuel
***See Troubleshooting section for additional information
Diagnostic Error Codes
display a visual indicator and sound an alarm if a fault is detected. Codes clear automatically when corrected or can be reset by
interrupting power to the control for 5 seconds. To silence an alarm, depress the ▼ on the keypad.