background image

Page 4 of 4

Advanced Modern Technologies Corporation

19800 Nordhoff Place, Chatsworth, CA 91311

Tel: (818) 883-2682  Toll Free: (800) 874-7822  Fax: (818) 883-2620
www.amtcorporation.com

Warranty

AMTC WARRANTS THE ASD-600 SANITIZER DISPENSER TO BE FREE OF DEFECTS IN MATERIAL AND 
WORKMANSHIP FOR A PERIOD OF THREE (3) YEARS FROM DATE OF PURCHASE, WHEN PROPERLY 
INSTALLED AND UNDER NORMAL USE AND SERVICE. THESE PROVISIONS DO NOT INCLUDE THE 
BATTERIES SHIPPED WITH THE PRODUCT. A DEFECTIVE PRODUCT MAY BE RETURNED TO AMTC 
OR ITS AUTHORIZED REPRESENTATIVES WITHIN THREE (3) YEARS FROM DATE OF PURCHASE 
WITH THE PROPER INVOICE OF PURCHASE. AMTC, AT ITS DISCRETION, WILL REPLACE OR REPAIR 
DEFECTIVE PRODUCT AT NO CHARGE. CLAIMS FOR LABOR, TRANSPORTATION, AND ANY OTHER 
INCIDENTAL COSTS WILL NOT BE ALLOWED. AMTC WILL NOT BE RESPONSIBLE FOR ANY 
CONSIDERABLE DAMAGES OF ANY KIND WHATSOEVER.

FOR TECHNICAL SUPPORT PLEASE CALL TOLL FREE 1-800-874-7822 OR VISIT OUR WEBSITE 
AT 

WWW.AMTCORPORATION.COM.

MAKE SURE TO VISIT OUR WEBSITE PERIODICALLY FOR INFORMATION ON NEW PRODUCTS AND 
TO DOWNLOAD ANY IMPORTANT PRODUCT DOCUMENTS THAT YOU MAY NEED IN THE FUTURE.

  

Installation Template for Model ASD-600 Spout (Not used for Model ASD-600EL)

3-3/4” 

(95mm)

REF

Counter Top

Sink

Center Drill Point

1” (25.4mm) Hole

Spout Footprint

1-1/2” (38 mm)

(Scale 1:1)

Minimum 

To

Edge of Sink 

Basin

Dispenser can be installed 
on the left or right of the sink

Counter Top

Sink

REV. 03/20

ASD-600 HY-GENIE™ 

AUTOMATIC LIQUID SANITIZER DISPENSER 

INSTALLATION & OPERATION MANUAL

Summary of Contents for HY-GENIE ASD-600

Page 1: ...p through the spout In some cases there may be some trapped air in the system that does not allow the sanitizer to initially prime If this is the case you will need to blow through the sanitizer filter to clear the trapped air Then prime the sanitizer again The sanitizer should now prime through the spout For further assistance please call Technical Support at 1 800 874 7822 IMPORTANT PRE INSTALLA...

Page 2: ...anitizer bottle onto sanitizer bottle coupler and hand tighten 7 Connect sensor cable onto battery pack you will hear pumps and sanitizer will purge for approximately 5 seconds 8 Sanitizer dispenser is now ready for use Sanitizer Bottle Coupler Threaded Stem Low Battery Indicator Low Sanitizer Indicator Flashing BLUE LED Flashing RED LED Reset Button www amtcorporation com Attention Make sure sens...

Page 3: ...ed Replace all 4 batteries D size Sanitizer is low or empty Refill sanitizer bottle and press and hold reset button for 7 seconds to prime new sanitizer and reset LED Sanitizer does not come out of spout Spout filter is dirty and won t pump sanitizer through the spout Clean or replace spout filter assembly Sanitizer Refill Instructions Sanitizer dispenses very weak Wrong sanitizer was used and pum...

Page 4: ...ACE OR REPAIR DEFECTIVE PRODUCT AT NO CHARGE CLAIMS FOR LABOR TRANSPORTATION AND ANY OTHER INCIDENTAL COSTS WILL NOT BE ALLOWED AMTC WILL NOT BE RESPONSIBLE FOR ANY CONSIDERABLE DAMAGES OF ANY KIND WHATSOEVER FOR TECHNICAL SUPPORT PLEASE CALL TOLL FREE 1 800 874 7822 OR VISIT OUR WEBSITE AT WWW AMTCORPORATION COM MAKE SURE TO VISIT OUR WEBSITE PERIODICALLY FOR INFORMATION ON NEW PRODUCTS AND TO DO...

Reviews: