background image

Installation Diagram

Installation Instructions (refer to installation diagram above)

Battery Pack

4-D Size 

(Batteries Sold Separately)

Reset Button

Liquid Sanitizer Bottle

(800 mL)

Spout

Spacer

Sensor Cable

Mounting Bracket

Countertop or Sink

 Max. Thickness: 2” (50mm)

AD05

6 Volt AC Power Adapter

(Optional-Sold Separately)

(Optional)

1. If hole is not present drill a 1” (25.4mm) hole on countertop (refer to installation template on page 4).
2. Mount the spout onto the countertop or sink and hand tighten mounting bracket and spacer without damaging sensor cable.
3. Install batteries into battery pack and mount battery pack onto back wall using provided hardware 
    (battery pack must be installed within 15” (380mm) of spout).
    

Note: An optional 6 Volt AC power adapter (Part# AD05) can be purchased separately if electrical power is required.

4. Screw sanitizer bottle coupler onto threaded stem and hand tighten.
5. Fill up bottle with liquid or gel sanitizer.
6. Screw liquid sanitizer bottle onto sanitizer bottle coupler and hand tighten.
7. Connect sensor cable onto battery pack (you will hear pumps and sanitizer will purge for approximately 5 seconds).
8. Sanitizer dispenser is now ready for use.

Sanitizer Bottle Coupler

Threaded Stem

Low Battery Indicator

Low Sanitizer Indicator

Flashing BLUE LED

Flashing RED LED

Reset Button

www.amtcorporation.com

Attention: 
Make sure sensor cable is passed 
through the opening of the spacer 
to avoid damage.

Page 2 of 4

 

Parts List

A

C

F

Reset Button

www.amtcorporation.com

H

D

E

I

G

(Optional-Sold Separately)

ASD-600

ASD-600EL

A-1

Ref #

Description

Part #

A

C

D

E

F

G

H

Battery Pack

800ml Sanitizer Bottle

Mounting Screws

Sanitizer Bottle Coupler

Mounting Bracket

Spacer

Spout

ASD-6BP

ASD-6SB

ASD-6MSC

ASD-6SBC

ASD-6MB

ASD-6SPA

ASD-6SPT

I

AD05

6-Volt AC Power Adapter
(Optional)

J

AD05-2

6-Volt AC Power Adapter
w/Extension for 2 Devices

K

AD05-2-EXT

Extension Only for AC 
Power Adapter

A-1

EL Spout (6” Long) 

ASD-6SPTEL

B

B

Spout Filter Assembly

ASD-6FA

K

(Optional-Sold Separately)

J

(Optional-Sold Separately)

ASD-600 HY-GENIE™ 

AUTOMATIC LIQUID SANITIZER DISPENSER 

INSTALLATION & OPERATION MANUAL

Summary of Contents for HY-GENIE ASD-600

Page 1: ...p through the spout In some cases there may be some trapped air in the system that does not allow the sanitizer to initially prime If this is the case you will need to blow through the sanitizer filter to clear the trapped air Then prime the sanitizer again The sanitizer should now prime through the spout For further assistance please call Technical Support at 1 800 874 7822 IMPORTANT PRE INSTALLA...

Page 2: ...anitizer bottle onto sanitizer bottle coupler and hand tighten 7 Connect sensor cable onto battery pack you will hear pumps and sanitizer will purge for approximately 5 seconds 8 Sanitizer dispenser is now ready for use Sanitizer Bottle Coupler Threaded Stem Low Battery Indicator Low Sanitizer Indicator Flashing BLUE LED Flashing RED LED Reset Button www amtcorporation com Attention Make sure sens...

Page 3: ...ed Replace all 4 batteries D size Sanitizer is low or empty Refill sanitizer bottle and press and hold reset button for 7 seconds to prime new sanitizer and reset LED Sanitizer does not come out of spout Spout filter is dirty and won t pump sanitizer through the spout Clean or replace spout filter assembly Sanitizer Refill Instructions Sanitizer dispenses very weak Wrong sanitizer was used and pum...

Page 4: ...ACE OR REPAIR DEFECTIVE PRODUCT AT NO CHARGE CLAIMS FOR LABOR TRANSPORTATION AND ANY OTHER INCIDENTAL COSTS WILL NOT BE ALLOWED AMTC WILL NOT BE RESPONSIBLE FOR ANY CONSIDERABLE DAMAGES OF ANY KIND WHATSOEVER FOR TECHNICAL SUPPORT PLEASE CALL TOLL FREE 1 800 874 7822 OR VISIT OUR WEBSITE AT WWW AMTCORPORATION COM MAKE SURE TO VISIT OUR WEBSITE PERIODICALLY FOR INFORMATION ON NEW PRODUCTS AND TO DO...