background image

                               

                                                                           

 

                www.amtelectronics.com                                                                           www.amtelectronics.com  

           3                                                                                                  3

 

                                                                                                     

 
Rear panel. 

 

11.

 

DC 9V

-for connecting power adapter cable  jack.

 

12.

   

A-DIR / A+DIR

 switch changes the device’s output fed  signals 

combination.

 

13.

 Bottom 

cover. 

 

  CAUTION! All connections are to be carried out only when 
the power of the preamp has been SWITCHED OFF! 
 

Changing delay line modes and their indications with TAP / 
SET button

  

TDD-3 delay line has two operation modes: 

1.

 

SET

-manual adjustment of delay time. 

2.

 

TAP

-quick adjustment of delay time (foot timing). 

Each mode is indicated by corresponding color (p.7): in  

SET -  RED

, in 

TAP -  

GREEN

. During operation the indicator’s blink intervals are equal to the set delay 

time. 
 The selection of the necessary operating mode is done by means of TAP / SET 
button (p.8). Switching between the modes is cyclical  - TAP – SET

 

 –  TAP – 

SET… etc..     
 To change mode from TAP 

to SET

 push TAP/SET button and hold it  for1-1.5 s 

(8) or change the position of D.TIME control (1) , the indicator color  (7) will change 
from green to red. In SET mode delay line will change the signal delay in 
accordance with time selected by D.TIME (1). The delayed and the number of its 
repetitions  will correspond to the settings of  E.LEVEL (2)and F.BACK (6) 
accordingly. 
 To change mode from SET to

 TAP

 briefly push TAP / SET (8), the indicator color 

will change from red to 

green

. In TAP mode you can quickly changed the delay 

time by means of foot timing. 
To do this push TAP / SET button twice (8) with the interval equal to the necessary 
delay time. After the first push the indicator (7) will turn red-green (the device is 
waiting for the second push) after the second one indicator (7) will blink blink green 
again (the device will accept the signal delay interval ). If by any reason the second 
push on TAP / SET button (8) does not happen for 3.35 s (the maximum possible 
delay time), the device will return to previous settings in this mode. The delayed 
signal level and number of its repetitions, like in SET mode, will correspond to the 
values set by E.LEVEL (.2) and F.BACK controls (6) accordingly. 
 

Changing modes and indication parameters by means of BYPASS 
button. 

 

BYPASS 

(9) button enables switching between “EFFECT” AND “BYPASS” modes. 

Modes change cyclically “EFFECT”  – “BYPASS”

 

 –  “EFFECT”   – … etc. In 

“EFFECT” mode the indicator (10) is red meaning that the output signal is being 
processed.  In “BYPASS” mode the indicator (10) is off and both output signals (

А

 

and 

В

) are unchanged. 

 

Changing output signals combinations by means of A-DIR / A+DIR 
switch. 

С

  

помощью

 

переключателя

 

A-DIR / A+DIR 

(

поз

.12), 

расположенного

 

на

 

задней

 

панели

 

прибора

производится

 

выбор

 

комбинаций

 

сигналов

подаваемых

 

на

 

выходы

 

изделия

 

во

 

время

 

работы

 

линии

 

задержки

 

исходного

 

сигнала

Возможные

 

комбинации

 

сигналов

 

на

 

выходах

 

прибора

 

в

 

зависимости

 

от

 

положения

 

переключателя

 “A-DIR / A+DIR” 

представлены

 

в

 

таблице

 1. 

By means of 

A-DIR / A+DIR switch 

(12) located on the rear panel of the device, 

you can select combinations of signals fed to the outputs during the delay line 
operation. Possible combinations of output signals related to A-DIR / A+DIR switch 
position are shown in Table 1. 

Table 1. 

Output 

Combination of Signals 

Switch positioned at 

A-DIR 

 

OUT A 

(4) 

DELAY

 (delayed, not inverted) 

OUT B / MONO

 (3) 

DIRECT

 (original) 

Switch positioned at

 A+DIR

 

OUT A 

(4) 

inverted DELAY

 (or 

inverted delayed) 

OUT B / MONO

 (3) 

DELAY

 (or not inverted 

delayed) 

 

 
 

For qualified personnel only. 

There are no user-serviceable components inside the device. 
The device repair must be done only by qualified specialists

.  

 

 
 

Battery replacement. 

Use batteries exclusively recommended by the 
manufacturer. 

To replace the battery: 

1.

  Remove the bottom cover of the device (13) by unscrewing 4 (four) 

fastening screws. 

2.

  Disconnect the old battery and remove it. 

3.

  Connect a new battery and put it in place of the old one. 

4.

  Replace the bottom cover and secure it in place by means of the 4 

(four) fastening screws.

 

 
 
 
 
 
 
 
 
 
 
 
AUDIO CONNECTIONS AND SWITCHING. 

CAUTION! All connections are to be carried out only 
when the power of the device has been SWITCHED 
OFF! 
Use only MONO-JACKS for TDD-3 connections.  
 

 

Possible audio connections between TDD-3 and external devices

 

Summary of Contents for TDD-3

Page 1: ... DIR A DIR switch 3 For qualified personnel only 3 Battery placing replacing 3 Audio connections and switching 4 Audio connections in A DIR mode 4 Audio connections in A DIR mode 4 Block diagram 4 References 4 IMPORTANT INSTRUCTIONS NON OBSERVANCE OF THE FOLOWING INSTRUCTIONS MIGHT RESULAT IN YOUR AMPLIFIER OR SPAEAKERS DAMAGE GUARANTEE IS VOID IF THE DAMAGES ARE CAUSED BY NON OBSERVANCE OF THESE ...

Page 2: ...vice on rotate Volume controls to extreme left position counter clockwise Always try to adhere to moderate volume level Specifications Use only external devices and accessories recommended by the manufacturer Powering the device from battery and power adapter AMT TDD 3 is powered both by battery DC 9V 6F22 and DC 9V external power adapter the required specifications are shown in Specifications If ...

Page 3: ...spond to the values set by E LEVEL 2 and F BACK controls 6 accordingly Changing modes and indication parameters by means of BYPASS button BYPASS 9 button enables switching between EFFECT AND BYPASS modes Modes change cyclically EFFECT BYPASS EFFECT etc In EFFECT mode the indicator 10 is red meaning that the output signal is being processed In BYPASS mode the indicator 10 is off and both output sig...

Page 4: ...______________________________________________________ AMT Electronics reserves the right to change the internal and external design of the device which won t decrease its consumer properties without preliminary notification In this connection the specifications and appearance of the device might differ from the ones shown in this document ...

Reviews: