background image

Detailed Description

Analog Section

Figures E2 diagrams A thru D shows the 
equivalent circuit of the analog section in 3 
different phases of operation. The system will 
perform conversions at a rate determined by the 
clock frequency 40,002 clock periods per cycle. 
(see Figure E1B shown earlier in this chapter for 
details of conversion timing).

Auto-Zero Phase I (Figure E2A) 

During the Auto-Zero, the input of the buffer is 
connected to V REF through switch 2, and 
switch 3 closes a loop around the integrator and 
comparator, the purpose of which is to charge 
the Auto-Zero capacitor until the integrator 
output dose not change with time. Also, 
switches 1 and 2 recharge the reference 
capacitor to V REF.

Input Integrate Phase II (Figure E2B)

During Input Integrate the Auto-Zero loop is 
opened and the Analog Input is connected to the 
Buffer Input through switch 4 and C REF if the 
input signal is zero, the buffer, integrator and 
comparator will see the same voltage that 
existed in the previous state (Auto-Zero). Thus, 
the integrator output will not change but will 
remain stationary during the entire input 
integrate cycle. If V 

IN

 is not equal to zero, and 

an umbalanced condition exists compared to the 
Auto-Zero Phase, the integrator will generate a 
ramp whose slope is proportional to V 

IN

.

Deintegrate Phase II (Figures E2C and 
Figures E2D)

During the Deintegrate phase, switch 5 is closed 
and a voltage which is V REF more positive 
than during Auto-Zero is impressed on the 
BUFFER INPUT. Thus the referance capacitor 
stores the equivalent voltage. This returns the 
output of the integrator to the zero crossing 
point established in Phase I. The time, or 
number of counts, required to do this is 
proportional to the input voltage.

E-4-1. Reference Voltage

The precision reference voltage required to do 
the A/D conversion is developed by IC201.  The 
zener voltage is attenuated to approximately -
0.5V .  This voltage is applied to IC2-7 . 

E-4-2. LED Display

The output format from IC2 is in Binary Coded 
Decimal (BCD) format. Each digit is scanned 
for 10 clock pulses. The scan sequence is D5 D4 
D3 D2 D1. This drives Q1 thru Q5, which in 
turn drivers the seven segment displays. The 
BCD data is converted to seven segment format 
by IC4. When the 620ES electronics are in open 
circuit or over-range mode the display flashes 

0000"

. IC5 is a 1 MHz oscillator which is 

divided by 10 by IC6. The 100 KHz clock 
output  then goes to IC2.

E-5.

Ohms-To-DC Converter

The ohms-to-DC converter generates a constant 
current which is passed through the device under 
test to develop the voltage measured by the A/D 
converter.

E-5-1. Constant Current Source

The constant current source is composed of 
IC201, IC202, Q202, D203  and their associated 
components.  The input to the constant current 
source is approxi1.05 volts, developed 
at IC201-7 and connected to IC201-13 through 
R209 and R210. The heart of the constant 
current source is the voltage-to-current 
converter.  A simplified schematic of this circuit 
is shown in Figure E-4 and described in Section 
E-5-2.  The amplifier of IC201-12 is an invertor, 
and its output is applied to IC201-9.  The 
amplifier of IC201-8 has unity gain due to the 
feedback through R213  .  Its output is applied 
to the inverting input of IC202-3.  The output of  
IC202-6 provides feedback to the non-inverting 
input of IC201-10.  This circuit operates to 
maintain the inverting input at IC202-3 and the 
non-inverting input at IC202-2 at the same 
potential.

Summary of Contents for 620ES

Page 1: ...L 09JUNE2011 REV E PHONE 512 858 4045 800 350 5105 website http www amptec com FAX 512 3858 4340 TOLL FREE IN USA 2 0 I 9999 Ohms Fullscale with 0 1 milliohm 100 Resolution 620ES Safety Igniter Tester...

Page 2: ...Requirements A 4 Setup and Use CHAPTER B 620ES FAILSAFE OHMMETER SPECIFICATIONS Table B 2 Specifications CHAPTER C REPLACEMENT OPTIONAL ANDACCESSORYITEMS C 1 Available Accessories and Options C 2 Tes...

Page 3: ...Safe Power Supply Scheme Figure E 1 Model 620ES Block Diagram Figure E 1B Analog to Digital Converter Timing Diagram Figure E 2 Analog Section of IC1 and IC2 Figure E 3 Constant Current Source Diagram...

Page 4: ...20ES Should the rechargeable batteries reach a low charge level a negative sign will apear on the display The 620ES has a battery monitoring circuit that indicates it is time to plug in the battery ch...

Page 5: ...On time An Overnight charge usually restores the 620ES to a Fully Charged ready to use state The main Power switch has two separate modes The ON position supplies internal battery isolated power to o...

Page 6: ...ithin minute s of power turn on unless your in an extremely cold temperature allow more time for warm up 15 minutes A quick check for no sign of the low battery indicator and test lead integrity check...

Page 7: ...20K ohm ranges 0 002 per C from 0 C 15EC and 35 C 50 C Instrument Display 20 000 count 4 digit Super Bright Light Emitting Diodes LED Over Range Indication select next higher range Display flashes Mea...

Page 8: ...Rack Mount Adapter Option 620RACK includes an adapter tray that allows any AMPTEC 620 series tester to be flush panel mount installed in a standard 19 equipment rack C 2 Test Lead Sets and Probes Opt...

Page 9: ...y interface A High Go Low BCD Dual Limit Comparator is presently under development and will be available Summer of 2001 Option 300 4 Wire Gold Plated Kelvin Lead Set Option 300 is a general purpose Go...

Page 10: ...e used for calibration purposes Simpsontm DC Milliammeter Range 0 10 mA fullscale Accuracy 3 FTSR1 01 23572 0 1W 1 0 Resistor Tc 25ppm C W FTSR2 01 23575 10 0W 0 1 Resistor Tc 10ppm C W FTSR3 01 23577...

Page 11: ...log 10 mA full scale milliammeter and a variety of test resistors is available from AMPTEC RESEARCH D 1 General Operation This section contains operating instructions for the AMPTEC 620ES Explosive Sa...

Page 12: ...O to output a single data string 1 resistance reading r0 De Selects all Ranges r1 Selects the 2 0 Ohm Range r2 Selects the 20 Ohm Range r3 Selects the 200 Ohm Range r4 Selects the 200K Ohm Range V Ve...

Page 13: ...20ES unless you are qualified D 3 4 Wire Resistance Measurement The four terminal configuration of the 620ES eliminates measurement errors normally caused by in series test lead resistance and contact...

Page 14: ...condition when ever the test lead terminals are open or the resis tance under test is a higher value than the range selected on the AMPTEC 620 tester Connecting VHI to IHI and Vlo to Ilo eliminates th...

Page 15: ...main power switch must be switched OFF to charge the batteries In the OFF position the main power switch disables all ohmmeter measurement circuitry and connects the internal battery pack to the char...

Page 16: ...iter Testers output terminals Imax Current Maximum Calculation 1 6V 110 ohms 0 014 Amperes 15mA max A simple startup test procedure which also has the 620ES Explosive Safety Tester user perform a func...

Page 17: ...on it usually means the batteries are dead and need charging or fuse needs replac ing If the 620ES exhibits problems that cannot be eliminated by reviewing Chapters B and D the following guidelines h...

Page 18: ...r move the replacement part until the solder has cooled Cold solder and bad solder joints can cause more problems Use the chassis ground connect to the common terminal of the functional test section c...

Page 19: ...s care of the digital part of the 4 digit 20 000 count dual slope conversion COUNTERS DISPLAY COMPARATOR BUFFER MULTIPLEXER ZERO CROSSING DETECTOR INTEG UUT CONTROL LOGIC INPUT SWITCH DC CONSTANT CURR...

Page 20: ...EGRATOR INTEGRATOR COMPARATOR COMPARATOR CAZ CAZ CSTRAY CSTRAY RINT RINT FIGURE E 2B PHASE ll INTEGRATE INPUT FIGURE E 2C PHASE lll AND DE INTEGRATE CINT CINT VIN VIN CREF CREF 3 3 1 1 2 2 6 6 5 5 4 4...

Page 21: ...ished in Phase I The time or number of counts required to do this is proportional to the input voltage E 4 1 Reference Voltage The precision reference voltage required to do the A D conversion is deve...

Page 22: ...C 620ESTester Igniter Tester schematic will show that the output of IC202 6 is actually applied to the base of transistor Q202 which acts as a current limiter The worst case component failure that cou...

Page 23: ...y Scheme The 5 volt power supply is provided directly by the batteries for driving the LED displays and digital logic The 5VD is used for driving IC8 the low battery detection circuit The 15V power su...

Page 24: ...ginning the calibration procedure The calibration adjustments are accessed by removing the screws in the feet of the unit then lifting off the lid to access the main PCB trimpots The locations of the...

Page 25: ...ents necessary for the 200 KOhm and 200 Kohm ranges Contact AMPTEC s customer service department if further technical support is necessary F 4 Battery Replacement Instructions The rechargeable NICAD b...

Reviews: