Copyright 2018-2020 Ampt, LLC.
All rights reserved.
27
Ampt String Optimizer V1500 Series
Installation Manual: 57070012-1H
Steps
1.
Read the warning and caution statements above.
2.
Follow your safety procedures and protocols to ensure the String Optimizer is not
under load.
3.
Follow your safety procedures and protocols to verify that there is zero current
flowing through the optimizer circuit by using a current clamp to test each wire
connected to Input 1, Input 2, and the output.
a.
If current is detected on any of these cables, wait for zero irradiance and
verify that there is zero current flowing through the optimizer circuit.
4.
If no current is detected, then use the Amphenol H4 connector unlocking tool to
disconnect connectors in the following order:
a.
Output
b.
Input 2
c.
Input 1