Ampt String Optimizer V1500 Series
Installation Manual: 57070012-1H
9.
Follow your safety procedures and protocols to measure the output voltage of
the String Optimizer. It should be equal to the maximum value of the Output
Voltage Range on the product label (+/- 15 volts). If it is not, contact Ampt.
Figure 12: Verify proper installation
10.
If you are connecting the output now, then proceed to the next section.
Otherwise, use Amphenol Sealing Caps to protect the connectors until the output
is connected.
Optimizer
output
from PV string
from PV string
Output Voltage Range
on the product label