13
Auto Power Off
20 min
Disable Auto Power Off
Hold LIMIT
Button down
and power up
SPECIFICATIONS
Display
6000 counts digit large scale
Sensing
True RMS
Update rate
5 per second nominal
Operating
temperature and
relative humidity
32 °F to 86 °F (0 °C to 30 °C)
(≤ 80% R.H.)
86 °F to 104 °F (30 °C to 40 °C)
(≤ 75% R.H.)
104 °F to 122 °F (40 °C to 50 °C)
(≤ 45% R.H.)
Storage
temperature
-4 °F to 140 °F (-20 °C to 60 °C)
(with battery removed)
Jaw opening
1.2 in (30 mm) max.
Pollution degree
2
IP rating
IP20
Operating altitude
≤ 2000 m
Overload
protection
600 V rms
Measurement
category
CAT III 600 V
Safety compliance
IEC 61010-1, IEC 61010-2-032,
IEC 61557-13
E.M.C.
Meets EN61326-1