Amphenol
PCD
Shenzhen
Application Specification for
HVSL60061/HVSL630062/
HVSL280063
Doc. No.:
APCD-TD-282
Rev.: H
Page 23 of 29
Subject:
Application specification for
HVSL600061/HVSL630062/HVSL280063
ECN NO.:
C5467N
Eff. Date:: 2021-5-20
F-0866-B
5.6 Strip the jacket shown as below.
5.7 Slide the inner ferrule until it is aligned with the cutting surface of the
jacket, then flip the shielding braid over to cover the ferrule, finally wrap 2-3
layers copper foil and cut all the filler shown as below.
5.8 Strip the insulation shown as below.
34.0±0.5mm
10.0±0.5 mm ref
5.0±0.5 mm
Wrap copper foil.
Cut the filler.
Move the inner ferrule to align it
with the cutting surface.
Flip over the shielding to
cover the ferrule.
Wrap copper foil.
Φ15.6±0.1 mm ref
When the cable OD is
small, add padding to
the cable jacket.