FI6000 | FIRE ALARM INTERFACE

PAGE 3

Schematic Diagram 

amperes

ACTIVE

DATA

POWER

PRIORITY 1

PRIORITY 2

24 CH DATA DECODER / RECEIVER

amperes

TD 6240

MENU

amperes

O

I

POWER

QP2500

UP

DOWN

Q

uantum

2000 SERIES

500W 100V LINE POWER AMPLIFIER

EP 1200A

SIREN

EMERGENCY / SIREN ACTIVE

PAGING

EMERGENCY PAGING PANEL

EMERGENCY

amperes

MIC

F I R E

POWER

OFF SELECT

TUNER

CD

CASS

OFF

MASTER

MUSIC SOURCE

SIG IN

BASS

MAX

MIN

EXT INPUT

MAX

MAX

MIN

SOURCE

MIN

SIG IN

CHIME

MIXER

TREBLE

MAX

MIN

TONE CTRL

CH5

CH6

CH4

SIG IN

SIG IN

SIG IN

MAX

MIN

MAX

MIN

MIN

CH3

CH1

CH2

SIG IN

SIG IN

MAX

MIN

MAX

MIN

MAX

MIN

MAX

AUX

SIG IN

PRE AMPLIFIER MIXER

amperes

MX 2222

O

I

ZS 5121

amperes

SPEAKER ZONE SELECTOR

2

1

3

5

4

6

7

8

9

10

12

11

ALL CALL

PAGING ZONE SELECTION

OVERRIDE

OVERRIDE

INPUT SOURCES

PD SERIES

PAGING MIC

MX2222

EP1200

AMPLIFIER

TD6240

TO SPEAKERS

data & audio

audio

trigger switching

& 100V line audio

100V audio

audio

audio

VC 24V trigger

VC 24V trigger

RS485

data

FI 6000

amperes

FIRE ALARM INTERFACE

RESET

STOP

SNOOZE

USB

INPUT & OUTPUT

5

6

3

4

7

8

1

2

13

14

11

12

15

16

9

10

21

22

19

20

23

24

17

18

CH3

CH4

CH1

CH2

RELAY OUTPUT

FROM FIRE ALARM INTERFACE / BAS

SENSORS ( VOLTAGE FREE )

contact 2 to 4

MR 1301

amperes

DOWN

UP

MENU

ENTER

PRE

NEXT

SHIFT

MSG 1

MSG 2

MSG 3

MSG 4

MSG 5

MSG 6

MSG 7

MSG 8

DIRECT MESSAGE TRIGGER

MESSAGE REC / PLAYER

INPUT

REC MIC

REC

trigger contact ( s )

MR1301

(trigger EP 24V override)

audio out to MX2222

or EP1200

FI6000

In the above application, FI6000 shall be used to generate systematic auto voice announcement according to the preset zones. 

The inputs section shall be connected to external sensors or Fire Alarm System and in any event, it shall trigger the required zone 

via TD6240 / ZS5121 and plays required message via MR1300 ( MR1301 ).

RS485 data from FI6000 can be used to trigger TD6240 or TD6080 as well as MR1301.

Additional dry contact port of FI6000 can be used to trigger Volume Control overriding ( through EP1200 ).

The sequence of activities ( tasks ) has to be set accordingly to avoid loss of communication. Such as, when channel 2 is 

triggered :

> Trigger EP VC Override >> Trigger Zone 1,3,4 >>>Trigger Message 1

The sequence can be set using the Configurator Software provided.

ZS5121 / ZS5122

Summary of Contents for FI6000

Page 1: ...ipment such as zone decoder and voice message player for interfacing with Fire Alarm System As part of requirement of EN54 it is necessary that voice alarm to be broadcasted according to zone s for or...

Page 2: ...source to your installation 6 RS485 DATA PORT RS485 data port is used to interface with other Amperes products to enable simpler cabling or interconnection works Alternatively it can be linked to PC...

Page 3: ...TOP SNOOZE USB INPUT OUTPUT 5 6 3 4 7 8 1 2 13 14 11 12 15 16 9 10 21 22 19 20 23 24 17 18 CH3 CH4 CH1 CH2 RELAY OUTPUT FROM FIRE ALARM INTERFACE BAS SENSORS VOLTAGE FREE contact 2 to 4 MR 1301 ampere...

Page 4: ...dio out to EP message in via MR1301 MxP2288 EP1200 FI6000 MR1301 TD6080 Zones MR 1301 amperes DOWN UP MENU ENTER PRE NEXT SHIFT MSG 1 MSG 2 MSG 3 MSG 4 MSG 5 MSG 6 MSG 7 MSG 8 DIRECT MESSAGE TRIGGER M...

Page 5: ...miniature PLC unit If the device connected to PC this info shall appear Address of the unit Destination port on the PC States version number at firmware FI6000 Icon Device Setup PC Interface Connect...

Page 6: ...for interfacing Unused channel will not be shown by the green LED If ticked tasked performed by one channel will be followed by the next activated channel determine the duration of a snooze in second...

Page 7: ...e 24 boxes with each represent an input channel Upon activation of each channel the system shall look up to the relevant box to obtain the data on which zone to trigger Diagram as at page 9 Example wh...

Page 8: ...hall be entered MR Address Message ID Repeat Tick box select corresponding MR address if there are several units installed in the system refers to the message number of the corresponding MR number of...

Page 9: ...vate Zone 1 2 5 6 10 11 15 subsequently after 5 mins Activated Zone ALL Zones When any zone is triggered at first time activate Message 1 of MR1300 1 message recorder subsequently after 5 mins message...

Page 10: ...elated Tasks press Stop button but the related channel LED shall blink indicating that the channel is still at fault Reset With stop pressed the LED shall still blink showing the related fault is pres...

Page 11: ...ndication for each incoming sensors Input Operating voltage Current consumption at idle Current consumption at channel and relay trigger Power consumption at idle USB input Communication control Baud...

Page 12: ...rformed by unauthorized personnel or service centres This warranty covers only repairs and replacement of defective parts cost and risks of transportation as well as removal and installation of the pr...

Reviews: