background image

Warranty Conditions

Disclaimer

AMPERES ELECTRONICS SDN BHD

MADE IN MALAYSIA

Published : JANUARY 2020

ISO 9001: 2015

Design & Manufacture of Public Address Equipment and Systems

Certificate No. 16895 / A / 0001 / UK / En

Information contained in this manual is subject to change without prior notice and does not represent a 

commitment on the part of the vendor. AMPERES ELECTRONICS SDN BHD  shall not be liable for any loss or 

damages whatsoever arising from the use of information or any error contained in this manual.

It is recommended that all services and repairs on this product be carried out by AMPERES ELECTRONICS SDN 

BHD or its authorized service agents.

AMPERES series must only be used for the purpose they were intended by the manufacturer and in conjunction 

with this operating manual.

AMPERES ELECTRONICS SDN BHD cannot accept any liability whatsoever for any loss or damages caused by 

service, maintenance or repair by unauthorized personnel, or by use other than that intended by the manufacturer.

Only Amperes Electronics Service Centres are allowed to make warranty repairs : a list of Amperes Electronics 

Service Centres may be asked for by the purchaser or send directly to Amperes Electronics Sdn Bhd at 70 Jalan 

Industri PBP 3, Tmn Perindustrian Pusat Bandar Puchong, 47100, Puchong, Selangor, Malaysia or its authorized 

dealers. This warranty is not valid if repairs are performed by unauthorized personnel or service centres.

This warranty covers only repairs and replacement of defective parts ; cost and risks of transportation as well as 

removal and installation of the product from the main system are for the account of the purchaser. This warranty 

shall not extend to the replacement of the unit.

This warranty does not cover damages caused by misuse, neglect, accident of the product as well as using the 

product with power supply voltage other than shown on the product, or any other power supply source / adaptor 

not recommended by the manufacturer.

This warranty does not cover damages caused by fire, earthquakes, floods, lightning and every cause not directly 

related to the unit.

This warranty does not include any indemnity in favor of the purchaser or the dealer for the period out of use of the 

unit; moreover the warranty does not cover any damages which may be caused to people and things when using 

the product.

This warranty certificate is valid only for the described product, and is not valid if modifications are made on this 

certificate or on the identification label applied on the product.

This warranty covers all the material and manufacturing defects and is valid for a period of 36 months from the 

date of purchase or for a specified period in countries where this is stated by a national law. In this case, the 

extension is valid only in the country where the product is purchased.

Amperes Electronics Sdn Bhd is not obliged to modify previously manufactured products under warranty if the 

design changes or improvements are made.

Summary of Contents for FI6000

Page 1: ...ipment such as zone decoder and voice message player for interfacing with Fire Alarm System As part of requirement of EN54 it is necessary that voice alarm to be broadcasted according to zone s for or...

Page 2: ...source to your installation 6 RS485 DATA PORT RS485 data port is used to interface with other Amperes products to enable simpler cabling or interconnection works Alternatively it can be linked to PC...

Page 3: ...TOP SNOOZE USB INPUT OUTPUT 5 6 3 4 7 8 1 2 13 14 11 12 15 16 9 10 21 22 19 20 23 24 17 18 CH3 CH4 CH1 CH2 RELAY OUTPUT FROM FIRE ALARM INTERFACE BAS SENSORS VOLTAGE FREE contact 2 to 4 MR 1301 ampere...

Page 4: ...dio out to EP message in via MR1301 MxP2288 EP1200 FI6000 MR1301 TD6080 Zones MR 1301 amperes DOWN UP MENU ENTER PRE NEXT SHIFT MSG 1 MSG 2 MSG 3 MSG 4 MSG 5 MSG 6 MSG 7 MSG 8 DIRECT MESSAGE TRIGGER M...

Page 5: ...miniature PLC unit If the device connected to PC this info shall appear Address of the unit Destination port on the PC States version number at firmware FI6000 Icon Device Setup PC Interface Connect...

Page 6: ...for interfacing Unused channel will not be shown by the green LED If ticked tasked performed by one channel will be followed by the next activated channel determine the duration of a snooze in second...

Page 7: ...e 24 boxes with each represent an input channel Upon activation of each channel the system shall look up to the relevant box to obtain the data on which zone to trigger Diagram as at page 9 Example wh...

Page 8: ...hall be entered MR Address Message ID Repeat Tick box select corresponding MR address if there are several units installed in the system refers to the message number of the corresponding MR number of...

Page 9: ...vate Zone 1 2 5 6 10 11 15 subsequently after 5 mins Activated Zone ALL Zones When any zone is triggered at first time activate Message 1 of MR1300 1 message recorder subsequently after 5 mins message...

Page 10: ...elated Tasks press Stop button but the related channel LED shall blink indicating that the channel is still at fault Reset With stop pressed the LED shall still blink showing the related fault is pres...

Page 11: ...ndication for each incoming sensors Input Operating voltage Current consumption at idle Current consumption at channel and relay trigger Power consumption at idle USB input Communication control Baud...

Page 12: ...rformed by unauthorized personnel or service centres This warranty covers only repairs and replacement of defective parts cost and risks of transportation as well as removal and installation of the pr...

Reviews: