If charging with 6V gear, it will be 3-STAGE CHARGING
3-STAGE CHARGING
First Stage
- Bulk Charge: Delivers maximum charging amperage
to "wake up" any serviceable 6 volt battery. When battery reaches a
maximum safe predetermined voltage, the charger will automatically
move into Stage 2 of the charging process.
Second Stage
- Absorption: Maintains the maximum possible
charge at a constant, safe, predetermined voltage. During this phase,
the charging voltage remains constant, while the actual charging
current is reduced to allow for the maximum proper internal chemical
energy transfer. At the end of Stage 2, the charger will automatically
move into Stage 3 charge mode.
Third Stage
- Float Charge: Voltage is automatically maintained
and reduced to a predetermined level while current is adjusted for a
safe, effective battery charge.
1-Bulk charge 2-Absorption 3-Float
CUPPENT
VOLTAGE
1-Desulfation 2-Soft Start 3-Bulk Charge 4-Absorption 5-Battery Test 6-Recondition 7-Float
CUPPENT
VOLTAGE
14