1. Desulfation:
Pulse charges the battery to break down the
buildup of lead sulphate crystals. Lead sulphate crystals can
occur when a battery has been discharged or left unused for a
period of time, seriously affecting the performance and lifetime
of the battery.
2. Soft Start:
A slow steady buildup of the charging process that
limits the power supplied to protect the battery.
3. Bulk Charge:
The main part of the charge process where
80% of the charge is applied.
4. Absorption:
Fully charges the battery by slowly reducing the
charge rate to allow the battery to absorb more power.
5. Battery Test:
An automatic test to determine the battery
condition after charging. If further charging required the Recondi
tion stage is selected, if fully charged the battery goes into Float
status.
6. Recondition:
Unique charge state to recover deeply
discharged batteries.
7. Float:
Maintains the battery at 100% charge without
overcharging or damaging the battery, allowing the Smart
Charge to be left connected to the battery indefinitely. Ideal for
batteries used intermittently, such as seasonally used vehicles
including classic cars, motorcycles
Note:
The Float process takes 5-10 minutes to fill the battery. DO
NOT disconnect the connection (AC\DC) during this time. If
disconnect the DC connection or the battery is filled, the digital
display will automatically turn off 5-10 minutes later.
13