3.6.3 Shut ting down the en gine
•
Set the RPM le ver (2) to idle.
•
Let the en gine run for about 5 min.
•
Turn the ig ni tion key (3) to «
0
».
•
Charge in di ca tor (4) and oil pres sure light (5) go on.
•
Re move the ig ni tion key.
•
Turn the fuel valve (1) «
S
» (closed).
3. Op er a tion
56
2
B6599503.cdr
STOP
ca. 5 min.
Danger
When work is over, or dur ing breaks, pro tect the
ig ni tion key from un au tho rized ac cess.
Important
If the en gine con tin ues run ning, set the RPM le ver (2)
to «STOP» and close the fuel valve (1).
L 40_010.cdr
S
1