Wiring For 1 Light Control Zones (Maximum Fixtures Per Zone)
Control Zone #1
Wiring
(16) - Down Lights [LP6]
Diagram #1
Wiring For 2 Independent Light Control Zones (Maximum Fixtures Per Zone)
Control Zone #1
Control Zone #2
Wiring
(4) - LP6
(9) - 2'x2' Ceiling Image [IDP]
Diagram #3
(2) - Directionals [LPD]
(9) - 2'x2' Ceiling Image [IDP]
Diagram #3
(8) - Directionals [LPD]
(12) - Down Lights [LP6]
Diagram #3
(4) - Down Lights [LP6]
(12) - Down Lights [LP6]
Diagram #3
(4) - 2'x2' Ceiling Image [IDP]
(12) - Down Lights [LP6]
Diagram #3
(8) - 2'x2' Ceiling Image [IDP]
(8) - Down Lights [LP6]
Diagram #2
(8) - Down Lights [LP6]
(8) - Down Lights [LP6]
Diagram #2
Wiring For 3 Independent Light Control Zones (Maximum Fixtures Per Zone)
Control Zone #1
Control Zone #2
Control Zone #3
Wiring
(4) - 2'x2' Ceiling Image (IDP)
(4) - Down Lights [LP6]
(8) - Down Lights [LP6]
Diagram #4
(4) - 2'x2' Ceiling Image (IDP)
(2) - Directionals [LPD]
(8) - Down Lights [LP6]
Diagram #4
(4) - Down Lights [LP6]
(4) - Down Lights [LP6]
(6) - 2'x2' Ceiling Image [IDP]
Diagram #4
(2) - Directionals [LPD]
(4) - Down Lights [LP6]
(8) - 2'x2' Ceiling Image [IDP]
Diagram #4
(8) - Directionals [LPD]
(4) - Down Lights [LP6]
(8) - Down Lights [LP6]
Diagram #4
(4) - Down Lights [LP6]
(4) - Down Lights [LP6]
(8) - Down Lights [LP6]
Diagram #4
Wiring For 4 Independent Light Control Zones (Maximum Fixtures Per Zone)
Control Zone #1
Control Zone #2
Control Zone #3
Control Zone #4
Wiring
(4) - 2'x2' Ceiling Image [IDP] (2) - Directionals [LPD]
(4) - Down Lights [LP6]
(4) - Down Lights [LP6]
Diagram #5
(4) - Down Lights [LP6]
(4) - Down Lights [LP6]
(4) - Down Lights [LP6]
(4) - Down Lights [LP6]
Diagram #5
(8) - Directionals [LPD]
(4) - Down Lights [LP6]
(4) - Down Lights [LP6]
(4) - Down Lights [LP6]
Diagram #5
(4) - 2'x2' Ceiling Image [IDP] (4) - Down Lights [LP6]
(4) - Down Lights [LP6]
(4) - Down Lights [LP6]
Diagram #5
Wiring For 1 Light Control Zones (Maximum Fixtures Per Zone)
Control Zone #1
Wiring
(12) - 2’x2’ Ceiling Image [IDP]
Diagram #6
(24) - 2’x2’ Ceiling Image [IDP]
Diagram #7
This supply can be used to remotely power any of PDC “ethernet wiring” fixtures. The power supply can be wired to control up to 4
independent controlled light zones. Use the table below to determine the correct wire diagram (wire diagram 1-5) for the number of zones
and types of luminaires on each zone
Any standard 3-way 0-10V dimmer can be used. PDC recommends using Lutron Diva (DVSTV) or Leviton IllumaTech (IPX12) . When the
0-10V wires are shorted together that zone will shut off. If another 0-10V dimmer is used it must be wired so the common of the switch is
connected to the gray dimming wire and the normally open wire is connected to the violet wire of the switch.
Electrical Connections:
Emergency backup:
The PSF16 power supply is capable of connection directly to an IOTA
125W battery backup. This unit can be purchased directly from
PDC (part number
3-23-000203
). Refer to
Wiring Diagram #8
for
electrical connections
Note:
Emergency operation when wired per
Wiring Diagram #8
the fixture
will operate as normal when normal AC is present. During the loss
of AC the unit will turn on luminaires #1 - #4 to full level. All of the
other luminaires in the room will go to a full dim level