Button
Name
Function
K
Total Lock-Out
Press this button to lock ALL bed movement functions. Press it again to unlock the
functions.
L
Battery Indicator
Indicator will be GREEN when bed is plugged in and battery is charging. Indicator will be
AMBER when the bed is operating on battery power only and requires charging.
M
Maintenance Indicator
Indicator will be lit when an error is detected. The bed should be removed from operation
and sent for maintenance as soon as possible.
Q
Enable Button
Press this button to activate the scale functions.
R
Reset/Zero Button
Press this button to “zero” the scale. (i.e. resetting the scale).
This must be carried out BEFORE the patient enters the bed. Place the mattress and any
accessories onto the bed before resetting the scale.
S
Bed Exit Alarm Button
To activate the Bed Exit Alarm, press this button while the patient is in the bed. The alarm is
activated when a 50% loss-of-weight on the load cells is detected. The alarm will sound and
remain on until the patient is attended to and the button is pressed to silence the alarm.
T
Auto-Compensate Button
This feature allows staff to add or remove items from the bed without affecting the patient
weight reading.
To use the Auto-Compensate feature:
• Press the button and the LED will begin to blink and will continue blinking until the
weight is stable. The display will show “AUTO” during this time.
• When the LED stops blinking, items can be added or removed from the bed. (Max. of
120 lbs, without exceeding Safe Working Load).
• After the items have been added/removed, press the button again and wait for the
LED to stop blinking.
• Press the Scale Button to display the patient weight. The LED above the Auto-
Compensate will illuminate with the Scale LED to indicate that the reading has been
“compensated”.
U
Volume Control
Press this button to alternate between the three Volume levels (indicated by the LEDs).
V
Scale Button
Press this button to measure the weight of the patient. The display will flash the weight and
become solid when the weight is stable.
To switch between Pounds (lbs) and Kilograms (kg), press the Scale (V) and Accuracy (X)
buttons simultaneously and hold for 5 seconds. The Display will automatically change to
the other unit.
W
Display
Displays the weight or error codes.
X
Accuracy Button
Press this button to display the patient weight to an accuracy of one decimal place.
e.g., Default display of the patient weight is 185 lbs. Pressing the Accuracy Button shows
184.8 lbs.
Footboard Controls
NOTE:
Buttons A, B, C, D, E, F, G, H,I and J are same functionality as siderails buttons.