background image

22

Silencer Cover
Silencer Bend
Left Board
Back Door
Fixing Sleeve For  Observing Bore
Fixing Sleeve For Input Of Fule Tank
Main Cover
Swich
Air Filter Baffle
Accelerator Electomagnet
Right Board
Output Panel Assembly
Cover Of Observing Bore For Air Filter
Cover Of Fuel Tank
Buoy For Oil Leverl Indication
Fuel Tank
Lining
Shock Absorption Mat
Clip
Clip
Fuel Inlet Pipe
Fuel Filter Assembly
Fuel Inlet Pipe 
Fuel Leak-off Pipe
Cover Of U Type Chamfer
U Type Chamfer
Support Of U Type Chamfer
Output pipe
Gasket Of Silencer
Upper Silencer
Low Silencer
Back Cover Of Alternator
Bracket
Shock Absorption Mat
Tow Structure Of Accelerator
Electomagnet
Bracket Of Electomagnet
Long Cover
Chassis
Rolling Wheel On Chassis
Flat Key
Pin
Motherboard Of Accumulator
Accumulator
Bolt

Number

Part Description

Quantity

Part Number

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45

1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
4
1
1
1
1
1
4
4
4
1
1
1

AH6000LN001
AH6000LN002
AH6000LN003
AH6000LN004
AH6000LN005
AH6000LN006
AH6000LN007
AH6000LN008
AH6000LN009
AH6000LN010

AH6000LN011

AH6000LN012
AH6000LN013
AH6000LN014
AH6000LN015
AH6000LN016
AH6000LN017
AH6000LN018
AH6000LN019
AH6000LN020
AH6000LN021
AH6000LN022
AH6000LN023
AH6000LN024
AH6000LN025
AH6000LN026
AH6000LN027
AH6000LN028
AH6000LN029
AH6000LN030
AH6000LN031
AH6000LN032
AH6000LN033
AH6000LN034
AH6000LN035
AH6000LN036
AH6000LN037
AH6000LN038
AH6000LN039
AH6000LN040
AH6000LN041
AH6000LN042
AH6000LN043
AH6000LN044
AH6000LN045

Summary of Contents for AH6000LN

Page 1: ......

Page 2: ...perate it according to the manual instruction Otherwise serious personal injury and equipment damage will result So AMICO reconfirms that ou must to read and understand this manual before operating th...

Page 3: ...ted locations If it s necessary to run the generating set indoors be sure to provide the ad equate ventilation 3 BE CARE NOT TO BE SCALDED The muffler and the engine body are very hot while the engine...

Page 4: ...in injuries and accidents Be sure to discon nect any apparatus from the generating set or prior to starting Most appliance motors require more than their rated wattage for start up Do not exceed the...

Page 5: ...Generating Set Operate the Generating Set Load Stop the Generating Set Periodic Checks and Service Long term Storage Troubleshooting and Remedy Detail Diagram Panel Detail Diagram Wiring Diagram LIMI...

Page 6: ...d r min Power factor cos Excitation mode DC output Operation mode Coupling method Engine Model Gross weght kg Overall dimensions LxWxH mm AH6000LN Generator 60 6 0 120 240 50 25 3600 1 12V 8 3A 12 hou...

Page 7: ...2 Outlet fo cooling air Fuelfiller cap Lifting eye Low oil pressureg lamp Exhaust AC output DC output Engine starter switch 2 CONFIGURATION 2 1 Parts name...

Page 8: ...will result Do not overdill Overfilling is very dangerous De not fill the tank beyond the top of the red plug inside the fuel oil fillter 3 PREPARATION FOR STARTING WARNING Refuel in a well ventilate...

Page 9: ...stops the engine automatically when the oil level falls below the lower level This prevents accidents such as bearing seizures etc Select the most applicable engine oil It is very important to select...

Page 10: ...t electdc shocks 3 4 Check the generating set 1 Turn off the main switch and any other loads Be sure to turn offthe main switch before starting The generating set should be earthed to prevent electric...

Page 11: ...hould always be kept in the ON position during operation Before starting the engine be sure to turn the switches of the working instru ment lighting apparatus motor etc to their OFF position If the sw...

Page 12: ...period Replace the engine oil on time Replace the engine oil while the engine is warm after 20 hours running the old engine oil will be drained out completely Approx one month or 20hours Every 3 mont...

Page 13: ...ore start ing it again 1 Starting Open the fuel cock Set the engine speed lever at RUN position Run the starting motor for long time will cost the battery power greatly even burn out the molor Always...

Page 14: ...same with generator s anode cathode line check volt if it is 12 3V otherwise must electricize 2 every month check volt if it is right free charge maintenance battery s charge volt is 13 5V 14 5v 3 che...

Page 15: ...just either the engine speed limiting bolt or fuel injection limiting bolt otherwise the performance will be affected 5 2 Checks during the running 1 Whether there is abnormal sound or vibration 2 Whe...

Page 16: ...quipment to the generating set in order Forthematterofthemotor load firsPy the heavy duty motor should be connected then the light duty motors If the operation is false the generating set will lag or...

Page 17: ...ged excessive current flows the fuse for the direct current will burn out Do not run the generating set while it is still connected with the battery Do not use DC12V and AC at the same time CAUTION Ba...

Page 18: ...s to the generator set 300VA TYPE WATTAGE STARTING RATED TYPICAL APPLIANCE EXAMPLE APPLIANCE STARTING RATED Incande scent lamp Heating applian ce Xl Xl Incandescent lamp TV 100W I00VA W I00VA W Fluore...

Page 19: ...r of the generating set 3 Set the speed lever at RUN position run the generating set without load for about 3 minutes Do not stop the engine suddenly otherwise the temperature will increase abnormally...

Page 20: ...eakage Check and tighten fasten ing parts bolts Tighten the Cylinder head Replace engine oil First time Secondtime Clean engine oil filter Replace if necessary Replace air cleaner element Service more...

Page 21: ...500 hours Replace if necessary 8 3 Replace the air cleaner element Do not clean the air cleaner element with detergent Replace time Every 6 months or 500 hours Never run the engine without the elemen...

Page 22: ...from the filler port 3 Wash the filter thoroughly with diesel fuel Loosen the fastening nut bottom cover and delivery discs for cleaning the deposit carbon 8 5 Tighten cylinder head bolt Tightening t...

Page 23: ...riods make the following preparations 1 Operate the engine for about 3 minutes and then stop 2 Stop the engine Drain the engine oil while the engine is still warm and fill with fresh oil 18 Oil filler...

Page 24: ...Remove the nozzle and repair it at test table Set the leverto START position The specified oil level should be between the upper level and lower level Clean the nozzle Start the engine according to th...

Page 25: ...20 11 DETAIL DIAGRAM...

Page 26: ...21...

Page 27: ...is Rolling Wheel On Chassis Flat Key Pin Motherboard Of Accumulator Accumulator Bolt Number Part Description Quantity Part Number 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 2...

Page 28: ...lt M6 12 Bolt M10 45 Bolt M6 16 Bolt M8 25 Bolt M6 12 Bolt M5 8 Bolt M6 Nut M8 Nut Flat Spring Washer M10 Nut Flat Spring Washer M5 12 Bolt M6 22 Bolt 46 47 48 49 50 51 52 53 54 55 56 57 58 1 1 1 1 1...

Page 29: ...24 12 PANEL DETAIL DIAGRAM...

Page 30: ...LN088 AH6000LN089 AH6000LN090 AH6000LN091 AH6000LN092 AH6000LN093 Panel M6X12 Bolt Starter Switch M4X30 Bolt 3 Prong Socket M4X15 Bolt M5X25 Bolt Positive DC Port Negative DC Port Grounded Bolt Integr...

Page 31: ...26 13 WIRING DIAGRAM...

Page 32: ...ted warranty shall be final This warranty does not cover 1 Merchandise sold as reconditioned used as rental equipment or floor or display models 2 Merchandise that has become damaged or inoperative be...

Page 33: ...Gregg Road Pico Rivera CA 90660 U S A Tel 562 908 0088 Fax 562 908 1899 Website www amicousa com Model No Engine Serial No Purchase Date Purchased from Retail location Private Consumer Other Name Add...

Page 34: ...ccupation Place of purchase Packaging conditions Operating conditions Parts Conditions Malfunction problem Opinions or suggestions Note Please mail the above card to Amico International Corp 4825 Greg...

Page 35: ...Air cooled Diesel Generator Set Kit Plastic cover Plug and power supply 1 2 3 4 5 1 1 1 1 2 Attached technical documents Order No Name Qty Remarks 1 1 1 1 1 1 2 3 4 Air cooled diesel generator manual...

Reviews: