13
Valve adjustment
Valve adjustment should be done with the control knob set at Burner ON saving flame po
‑
sition.
Remove the knob, and adjust the flame with a tiny screwdriver (see fig. 7 below).
Fig. 7
Checking the adjusted flame: heat the burner at full open position for 10 minutes. Then turn
the knob into the saving setting. The flame should not extinguish nor move to the nozzle. If
it goes off or moves over to the nozzle, readjust the valves.
These adjustments must be performed by a qualified and Gas Safe
Registered installer, service agency or gas supplier. All the relevant
safety regulations must be observed.
Failure to observe this policy may affect your warranty
INSTALLATION