12
INSTALLATION
Table 2
Replacement of burner nozzle: loosen the nozzle with a dedicated
wrench (7). Fit the new nozzle, suitable for the required gas type
(see table above for reference).
After you have converted the cooktop to another gas type, make sure you have
placed a label containing that information on the appliance.
Adjustment of the reduced valve flow
Burners
Flame
Converting the
cooktop from LPG
to natural gas
Converting the co
‑
oktop from natural
gas to LPG
Regular burners
Full flame
Replace the burner
nozzle according
to the guidelines in
table 1
Replace the burner
nozzle according
to the guidelines in
table 1
Saving flame
Loosen the adjust
‑
ment spindle (see
fig. 7) and adjust the
flame
Loosen the adjust
‑
ment spindle (see
fig. 7) and adjust the
flame