OPERATION
Residual heat indicator
When the hot heating zone is switched off, „H” is displayed as the signal meaning „heating
zone is hot!”.
During that time do not touch the
heating zone as you may burn your-
self and do not put on it any objects
that are sensitive to heat!
When the indicator goes off, you can touch
the heating zone but beware that it still has
not cooled down to the ambient tempera-
ture.
When power is not supplied, the
residual heat indicator is off.
Operating time limitation
In order to increase operational reliability,
the induction plate has an operating time
limiter for each heating zone. The maximum
operating time is determined according to the
previously selected level of heating power.
If you do not change the heating power le-
vel for a long time (see table), the relevant
heating zone is switched off and the residual
heat sensor is activated. However, at any
time you can switch on and operate speci-
fic heating zones, according to the user’s
manual.
Heating power
level
Maximum ope-
rating time in
hours
1
6
2
6
3
5
4
5
5
4
6
1,5
7
1,5
8
1,5
9
1,5
P
0,16