Adapting the cooker to another
type of gas.
This operation may only be carried out by an
appropriately authorised fitter.
If the gas the cooker is to be supplied with
differs from the gas provided for the cooker
by the manufacturer, that is G20 20 mbar,
burner nozzles must be exchanged and the
flame needs to be adjusted.
In order to adapt the cooker to burn a different
type of gas, you should:
exchange nozzles (see tables below),
adjust the “economical” flame.
Caution!
The cookers provided by the manufacturer
have burners which are factory-adapted to
use the gas specified on their data plates and
guarantee cards.
INSTALLATION
Burner of SOMIPRESS type
(according to the “Somipress” symbol on burner components)
In order to perform adjusting operations, take off the knobs. Adjusting elements of the oven
burner are accessible after drawing out the oven chamber floor.
Type of gas
Burner
auxiliary
gas injector
diameter
[mm]
medium
gas injector
diameter [mm]
large
gas injector
diameter [mm]
oven
gas injector
diameter
[mm]
nominal
thermal power
1,00 kW
nominal
thermal power
1,80 kW
nominal
thermal power
2,80 kW
nominal
thermal power
2,80 kW
G20 2H 20 mbar
G20 2E+ 20/25 mbar
0,72
0,98
1,17
1,30
G30/31 3+ 28-30/37 mbar
G30 3B/P 37mbar
0,52
0,67
0,83
0,84
Exchange of a burner noz-
zle – unscrew the nozzle
with special socket span-
ner No 7 and replace with
a new one according to a
type of gas (see tables).