Reassembling the "EBS" filter:
Before reassembling, visually check that all components are complete and in good mechanical condition.
Before reassembling, carefully read the safety instructions in chapter 2 of this document and make sure that all the workers at the
filtration site are fully aware of and comply with, these and any other local safety instructions.
1.
Install the seals (6) on the screen (7) and insert the screen into the filter housing (1). Make sure to handle the screen
according to the description provided in the “Extracting the Screen” section above.
2.
Position the scanner (14) in the filter housing. Make sure the lower shaft goes through the bearing (4).
3.
Apply some grease to the suction scanner shaft (2 on page 24) and to the O-rings (3 and 5).
4.
Lower the filter lid (9) carefully toward the filter housing (1) in a horizontal position. Make sure the lid is centered with the
suction scanner.
5.
For centering the lid properly use the two centering sleeves together with two bolts (17) in opposite positions.
6.
Screw the rest of the housing bolts (17). Tightening opposite positioned bolts will achieve proper sealing.
7.
Locate the O-ring (12) in its groove under the shaft housing (13). Place the bolts (21) but do not yet tighten them firmly.
8.
Turn the drive shaft (3 on page 23) clockwise until it reaches the suction scanner shaft. Insert the connecting pin (22) into the
hole in the drive shaft through the suction scanner shaft hole.
9.
Insert the split pin (23) in its original position.
10.
Make sure that the drive shaft key (24) is in its place. Apply grease to it and reassemble the drive unit (25).
11.
Firmly tighten the shaft housing bolts (21) and the drive unit bolts (29) in a controlled and balanced method.
12.
Reassemble the limit switches sling (9 on page 23); make sure the limit switches (22 on page 23) are tight in their place.
13.
Reassemble the exhaust valve and air tubes.
14.
Make sure that all bolts are tightened.
15.
Switch on the compressed air supply and switch on the power. The motor will run until limit plate (2 on page 23) reaches the
lower limit switch.
16.
Press the "test" push button and make sure the filter works according to the stages of the cleaning cycle.
17.