VIII. TROUBLE SHOOTING
TROUBLE
CAUSE
REMEDY
Motor does
not run
1. Button does not work
2.Wiring connections are not in good
condition
3. Motor burned out
4. AC contactor burned out
5. Height limit switch is damaged
1.Replace button
2.Repair all wiring connections
3.Repair or replace motor
4.Replace AC contactor
5.Replace
Motor runs
but the lift
is not raised
1.Motor runs in reverse rotation
2. Release valve in damage
3. Gear pump in damage
4.Relief valve or check valve in
damage
5.Low oil level
1.Reverse two power wire
2.Repair or replace
3.Repair or replace
4.Repair or replace
5.Fill tank
Lift does
not stay up
1. Release valve out of work
2 Relief valve or check valve leakage.
3.Cylinder or fittings leaks
Repair or replace
Lift raises
too slow
1.Oil line is jammed
2.Motor running on low voltage
3. Oil mixed with Air
4.Pump leaks
5.Overload lifting
1.Clean the oil line
2.Check electrical system
3. Fill tank
4.Replace Pump
5.Check load
Lift cannot
lower
1. Safety device are in activated
2. Release valve damaged
3. Air Cylinder damaged
4. Oil system is jammed
1. Release the safeties
2. Replace or repair
3.Replace the cylinder
4. Clean the oil system
Summary of Contents for PRO-18A
Page 1: ...FOUR POST LIFT Model PRO 18A ...
Page 9: ... 7 D Install cross beams See Fig 11 Fig 12 Fig 11 Fig 12 2 Hole towards inside 1 3 3 ...
Page 23: ... 21 P Install spring and safety cover of cross beam See Fig 32 Fig 32 3 3 3 8 40 3 2 ...
Page 26: ... 24 CROSS BEAM CYLINDERS Fig 35 Fig 36 3 ...
Page 27: ... 25 MANUAL POWER UNIT Fig 37 Manual 220V 60Hz 1PH ...
Page 34: ... 32 ...
Page 37: ... 35 ...